Remote operation over Wi-Fi
A tablet can serve as the operator panel. Results, time series, settings and diagnostics are available in a browser.
A high-sensitivity in-situ analyser for direct measurement of very low nitrogen-dioxide concentrations. Its extended resonator, High Grade mirrors and actively cooled LED provide the precision required for atmospheric research and clean-background work.
ICAD-NO₂-210L
The measurement cell is almost twice as long as the standard version and uses High Grade mirrors. Peltier cooling keeps LED temperature stable to better than 0.1°C, improving accuracy and reducing zero drift.
NO₂ is identified from its characteristic absorption spectrum around 430–480 nm. The measurement requires no analyte conversion, sample drying or NO₂ calibration gas.

The embedded computer performs analysis, data logging and health monitoring. The analyser can be accessed over Wi-Fi from a tablet, phone or computer.

A tablet can serve as the operator panel. Results, time series, settings and diagnostics are available in a browser.

The interface displays concentration traces and instrument parameters and allows averaging to be set from 1 to 60 s.
The graphical health table simplifies checking flow, temperature, voltage and component status. The design is insensitive to vibration, while automatic reference measurements reduce zero drift.

The colour-coded table shows operating values and their assessment, speeding up both on-site checks and remote diagnostics.

High stability, no consumable gases and internal data storage support long research campaigns and comparative measurements.
Parameters refer to the single high-sensitivity NO₂ path in a 19″ rack enclosure. Longer averaging reduces noise and improves the detection limit.
| Analytical performance | |
|---|---|
| Measured species | NO₂ — direct in-situ gas measurement by ICAD |
| Measurement range | 0–2000 ppb |
| Precision in the 2026 catalogue, 1σ | down to 0.12 ppb at 1 s and 0.02 ppb at 60 s |
| Additional values for other averaging times | |
| Detection limit from the model data sheet | 200 ppt at 2 s; 50 ppt at 30 s; 15 ppt at 300 s |
| Precision from the model data sheet, 1σ | 100 ppt at 2 s; 25 ppt at 30 s; 8 ppt at 300 s |
| Time resolution | 1–60 s averaging |
| Response time, 10–90% | 2 s at 1 l/min or 1 s at 2 l/min; dependent on cell type |
| Zero drift | less than 0.1 ppb/month; reduced in practice by regular automatic reference measurements |
| Temperature sensitivity | less than 0.01 ppb/°C |
| Factory time setting | 30 s on delivery; adjustable in the Web UI, with longer averaging improving accuracy through true internal spectral averaging |
| Spectral range | approximately 430–480 nm |
| Resonator cell | enhanced-sensitivity configuration; an almost twice as long cell with High Grade mirrors |
| Light-source stabilisation | active Peltier LED cooling; temperature stability better than 0.1°C |
| Selectivity | no significant spectroscopic cross-sensitivity; effects including H₂O, O₃, glyoxal and O₂ are eliminated or spectrally separated |
| Sample and calibration | |
| Sample flow | 1–2 l/min |
| NO₂ calibration | NO₂ calibration gas is not required; the analysis uses spectroscopic reference data and automatic zero checks |
| Optical-path characterisation | helium optional every 1–2 years; gas-free ICOM method subject to confirmation of availability in the current software version |
| Sample preparation | sample drying is not required; a PTFE aerosol filter is used in the sample path |
| Zero-air system | zero-air cartridge included; regular- and high-capacity systems are available |
| Consumable gases | none required during normal operation |
| Construction and power | |
| Housing | 19″ rack enclosure with front display |
| Dimensions | 43.8 × 13.2 × 66.5 cm |
| Weight | less than 12 kg |
| Power | 12 V DC; external ACC-PWR-8A power supply required |
| Power consumption | typically less than 40 W at 12 V |
| Start-up time | typically less than 1 min |
| Operating temperature | -10 to +25°C; up to +40°C with the cooling option |
| Mechanical stability | insensitive to typical vibration |
| Mobile use | the rack instrument can be used in suitably mounted and powered mobile installations; it is not an IP64 M-version |
| Communication, synchronisation and equipment | |
| Processing unit | internal industrial computer with measurement and diagnostic software |
| Data interfaces | LAN, Wi-Fi, RS232, Machine-to-Machine, OPC UA, Bayern-Hessen protocol and analogue voltage/current outputs |
| Data memory | internal storage for approximately 2 years of data |
| GPS | optional IC-ACC-GPSEXT module for geolocation and time synchronisation |
| Included equipment | large zero-air cartridge, PTFE aerosol filter holder with filter, 5 m PFA tubing and 3 m LAN cable |
| Options | operator tablet, GPS, ICAD cooling, integrated CO₂ sensor, PTFE filters, regular- or high-capacity zero-air system, maintenance and spare-part sets |
| Platform patents | EP3329251; DE 10 2015 000 423; US15/748,923; China ZL201680057099.6 |
The 210L is intended for work where standard sub-ppb sensitivity is not sufficient.
We will select the range, averaging time, cooling, communication, GPS and accessories for the expected NO₂ levels.