AIRYX · ICAD series · High Grade NO₂

ICAD-NO₂-210L

A high-sensitivity in-situ analyser for direct measurement of very low nitrogen-dioxide concentrations. Its extended resonator, High Grade mirrors and actively cooled LED provide the precision required for atmospheric research and clean-background work.

AIRYX ICAD-NO2-210L analyserICAD-NO₂-210L
15 pptdetection limit at 300 s averaging
8 ppt1σ precision at 300 s averaging
0–2000 ppbNO₂ measurement range
30 sstandard delivery setting
L version — enhanced sensitivity

A longer cell and a stabilised light source

The measurement cell is almost twice as long as the standard version and uses High Grade mirrors. Peltier cooling keeps LED temperature stable to better than 0.1°C, improving accuracy and reducing zero drift.

Direct ICAD spectroscopy

NO₂ is identified from its characteristic absorption spectrum around 430–480 nm. The measurement requires no analyte conversion, sample drying or NO₂ calibration gas.

single high-sensitivity NO₂ measurement path
resonator optimised for low concentrations
active Peltier cooling of the LED
automatic zero measurements to reduce noise and drift
averaging time adjustable in the Web UI
NO2 monitoring from clean background to high-traffic environments
Operation and integration

Full control without a separate application

The embedded computer performs analysis, data logging and health monitoring. The analyser can be accessed over Wi-Fi from a tablet, phone or computer.

Operating an AIRYX ICAD analyser from a tablet

Remote operation over Wi-Fi

A tablet can serve as the operator panel. Results, time series, settings and diagnostics are available in a browser.

AIRYX ICAD measurement interface

Results and measurement settings

The interface displays concentration traces and instrument parameters and allows averaging to be set from 1 to 60 s.

Measurement quality control

Diagnostics at a glance

The graphical health table simplifies checking flow, temperature, voltage and component status. The design is insensitive to vibration, while automatic reference measurements reduce zero drift.

ICAD graphical System Health diagnostics table

System Health

The colour-coded table shows operating values and their assessment, speeding up both on-site checks and remote diagnostics.

AIRYX ICAD analysers in a laboratory test setup

Research and comparison setups

High stability, no consumable gases and internal data storage support long research campaigns and comparative measurements.

Instrument technical data

ICAD-NO₂-210L specification

Parameters refer to the single high-sensitivity NO₂ path in a 19″ rack enclosure. Longer averaging reduces noise and improves the detection limit.

Analytical performance
Measured speciesNO₂ — direct in-situ gas measurement by ICAD
Measurement range0–2000 ppb
Precision in the 2026 catalogue, 1σdown to 0.12 ppb at 1 s and 0.02 ppb at 60 s
Additional values for other averaging times
Detection limit from the model data sheet200 ppt at 2 s; 50 ppt at 30 s; 15 ppt at 300 s
Precision from the model data sheet, 1σ100 ppt at 2 s; 25 ppt at 30 s; 8 ppt at 300 s
Time resolution1–60 s averaging
Response time, 10–90%2 s at 1 l/min or 1 s at 2 l/min; dependent on cell type
Zero driftless than 0.1 ppb/month; reduced in practice by regular automatic reference measurements
Temperature sensitivityless than 0.01 ppb/°C
Factory time setting30 s on delivery; adjustable in the Web UI, with longer averaging improving accuracy through true internal spectral averaging
Spectral rangeapproximately 430–480 nm
Resonator cellenhanced-sensitivity configuration; an almost twice as long cell with High Grade mirrors
Light-source stabilisationactive Peltier LED cooling; temperature stability better than 0.1°C
Selectivityno significant spectroscopic cross-sensitivity; effects including H₂O, O₃, glyoxal and O₂ are eliminated or spectrally separated
Sample and calibration
Sample flow1–2 l/min
NO₂ calibrationNO₂ calibration gas is not required; the analysis uses spectroscopic reference data and automatic zero checks
Optical-path characterisationhelium optional every 1–2 years; gas-free ICOM method subject to confirmation of availability in the current software version
Sample preparationsample drying is not required; a PTFE aerosol filter is used in the sample path
Zero-air systemzero-air cartridge included; regular- and high-capacity systems are available
Consumable gasesnone required during normal operation
Construction and power
Housing19″ rack enclosure with front display
Dimensions43.8 × 13.2 × 66.5 cm
Weightless than 12 kg
Power12 V DC; external ACC-PWR-8A power supply required
Power consumptiontypically less than 40 W at 12 V
Start-up timetypically less than 1 min
Operating temperature-10 to +25°C; up to +40°C with the cooling option
Mechanical stabilityinsensitive to typical vibration
Mobile usethe rack instrument can be used in suitably mounted and powered mobile installations; it is not an IP64 M-version
Communication, synchronisation and equipment
Processing unitinternal industrial computer with measurement and diagnostic software
Data interfacesLAN, Wi-Fi, RS232, Machine-to-Machine, OPC UA, Bayern-Hessen protocol and analogue voltage/current outputs
Data memoryinternal storage for approximately 2 years of data
GPSoptional IC-ACC-GPSEXT module for geolocation and time synchronisation
Included equipmentlarge zero-air cartridge, PTFE aerosol filter holder with filter, 5 m PFA tubing and 3 m LAN cable
Optionsoperator tablet, GPS, ICAD cooling, integrated CO₂ sensor, PTFE filters, regular- or high-capacity zero-air system, maintenance and spare-part sets
Platform patentsEP3329251; DE 10 2015 000 423; US15/748,923; China ZL201680057099.6
High Grade applications

When ppt-level performance matters

The 210L is intended for work where standard sub-ppb sensitivity is not sufficient.

Clean atmospheric backgroundlong-term monitoring of very low NO₂ concentrations
Atmospheric researchchemical processes, budgets and experiments that require high precision
Air-quality stationsurban and regional background work with ample sensitivity reserve
Laboratorieschamber studies, method comparison and reference work

Ask about ICAD-NO₂-210L

We will select the range, averaging time, cooling, communication, GPS and accessories for the expected NO₂ levels.

Contact MES-EKO