Interface and diagnostics
Graphs and the system-health table show results, gas flow, supply voltage and temperatures of critical components.
A dual-cell analyser for parallel NO and NO₂ measurement and determination of NOx. The first cell measures NO₂ directly by ICAD, while the second detects NO after selective conversion to NO₂. It is suited to air-quality monitoring and dynamic nitrogen-oxide measurements from combustion processes.
ICAD-NOx-210D
The two measurement cells operate simultaneously. The analyser therefore does not derive NO by subtracting sequential, time-shifted measurements and can resolve rapid changes in sample composition.
One path uses ICAD spectroscopy to measure NO₂ at approximately 430-480 nm. In the second, a patented NOx-free ozone generator converts NO to NO₂. The parallel signals provide NO, NO₂ and total NOx concentrations.
The embedded computer performs analysis, data storage and system health monitoring. The interface is available from a PC, tablet or phone without installing an additional app.

Graphs and the system-health table show results, gas flow, supply voltage and temperatures of critical components.

LAN, Wi-Fi, RS232, M2M, OPC UA, Bayern-Hessen protocol and optional voltage and current outputs.
Parameters for the D model measuring NO and NO₂. The stated LOD and precision apply to the direct NO₂ channel.
| Analytical performance | |
|---|---|
| Measured components | NO₂ - direct ICAD spectroscopy; NO - conversion to NO₂; calculated total NOx |
| Measurement arrangement | two cells for parallel detection of NO₂ and converted NO |
| Measurement range | 0-5000 ppb; custom configurations available |
| Time resolution | minimum averaging time 1 s |
| Delivery time setting | 5 s as standard; adjustable in the Web UI, with longer settings improving precision through true internal spectral averaging |
| Detection limit, 2σ | 0.09 ppb at 60 s for the NO₂ channel |
| Precision, 1σ | 0.40 ppb at 1 s; 0.05 ppb at 60 s for the NO₂ channel |
| Response time, 10-90% | below 2 s at 2 l/min; adjustable flow |
| Zero drift | below 0.1 ppb/month; automated zero measurements reduce noise and drift |
| Temperature sensitivity | below 0.01 ppb/°C |
| Spectral range | approximately 430-480 nm |
| Effective optical path | up to 2 km |
| Cross sensitivity | no significant spectroscopic cross sensitivity to carbon oxides, formaldehyde, ozone, methane, hydrogen, sulphur compounds, chlorine, ammonia and selected hydrocarbons; glyoxal is resolved spectrally |
| Sample, conversion and calibration | |
| Sample flow | 1-2 l/min |
| Sample preparation | sample drying is not required |
| NO conversion | patented internal NOx-free ozone generator; NO is converted to NO₂ in the second path |
| Path-length characterisation | helium every 1-2 years as an option or an NO₂ reference measurement; gas-free ICOM method subject to confirmation of availability in the current software version |
| NO₂ calibration | NO₂ calibration gas is not required; concentration is derived using literature absorption data |
| Converter calibration | NO gas above 1000 ppb, approximately every 12 months |
| Consumable gases | no gases required for normal operation |
| Operating conditions and construction | |
| Operating temperature | -10 to +25°C; up to +40°C with optional cooling |
| Start-up time | typically below 1 min |
| Power and consumption | 12 V DC; typically below 30 W |
| Mechanical stability | insensitive to ordinary vibration |
| Weight | below 10 kg, depending on configuration |
| 19-inch rack enclosure | 43.8 × 13.3 cm (3U) × 43.5 cm |
| IP64 enclosure, M variant | 43.6 × 13.2 × 30.0 cm |
| Control and communication | |
| Processing unit | embedded PC with analysis and measurement software |
| User interface | instrument panel and browser interface accessible through Wi-Fi |
| Data interfaces | LAN, Wi-Fi, RS232, M2M, OPC UA, Bayern-Hessen protocol; optional voltage and current outputs |
| Diagnostics | system-health table, gas-flow, supply-voltage and temperature checks; span adjustment in the interface |
| Data storage | internal memory for up to approximately two years of data |
| GPS | optional IC-ACC-GPSEXT module for geolocation and time synchronisation |
| Delivery, equipment and options | |
| Included equipment | large zero-air cartridge, PTFE aerosol filter holder with filter, 5 m PTFE tubing and 3 m LAN cable |
| Required items | ACC-PWR-8A external power supply; ACC-WIFIUSB module when Wi-Fi communication is required |
| Options and accessories | operator tablet, GPS, ICAD cooling, integrated NDIR CO₂ sensor, PTFE filters, regular- or high-capacity zero-air system, maintenance kit, spare parts and service options |
| Platform patents | EP3329251; DE 10 2015 000 423; US15/748,923; China ZL201680057099.6 |
The standard ICAD-NOx-210D is rack-mounted. Its corresponding M variant uses an IP64 enclosure for field installations.

For monitoring stations, laboratories and instrument cabinets, with an OLED front display.

The corresponding configuration for mobile campaigns and temporary outdoor installations.
The D model is intended for fast NO, NO₂ and NOx measurement without an additional CO₂ channel. It also fits mobile campaigns and road-traffic concentration studies. The dedicated Plume Chasing configuration with CO₂ measurement and emission-analysis software is ICAD-NOx-210DE.
For dedicated vehicle emission measurements using the Plume Chasing method, the recommended configuration is the ICAD-NOx-210DE, featuring integrated CO₂ measurement and vehicle emission analysis software.
We will define the range, enclosure, sample conditions, interfaces and equipment required for the installation.