Parallel gas analysis
NO₂ is measured directly, NO after conversion to NO₂, and CO₂ by an independent dual-wavelength NDIR sensor.
A dual-cell NO, NO₂ and NOx analyser with an integrated NDIR CO₂ sensor. The DE model measures diluted exhaust plumes and derives real-time NOx/CO₂ emission factors without removing the target vehicle from traffic.
ICAD-NOx-210DE
The measurement vehicle follows a selected car and samples its diluted exhaust plume. A CO₂ increase identifies the event, while the NOx/CO₂ ratio accounts for fuel consumption and current engine load.
The direct ICAD channel measures NO₂, the second channel detects NO after ozone conversion and the internal NDIR sensor records CO₂. The software identifies the plume, combines the signals and calculates NOx and NO₂ emission factors in mg/km or mg/kWh.
The system retains the speed required for short emission events. The sample does not need pre-drying, and the analyser is insensitive to ordinary vibration during mobile operation.

NO₂ is measured directly, NO after conversion to NO₂, and CO₂ by an independent dual-wavelength NDIR sensor.

Two flexible bumper inlets merge through a T-piece into one sample line. The assembly width is adjustable from 170 to 220 cm.
A wireless tablet guides the operator through each measurement. The interface shows event validity, CO₂ signal strength, NOx and CO₂ traces, the calculated emission factor and assigned emission class.
A preliminary vehicle screening can take approximately 15 seconds, while a complete valid measurement can take up to one minute. Log files are created automatically for the final campaign report.
Parameters of the DE instrument and its mobile-emission application configuration.
| Analytical performance | |
|---|---|
| Measured components | NO₂ - direct ICAD spectroscopy; NO - conversion to NO₂; calculated NOx; CO₂ - internal NDIR sensor |
| Measurement arrangement | two parallel ICAD cells and a dual-wavelength NDIR CO₂ sensor |
| NO and NO₂ range | 0-5000 ppb for each component; custom ranges are available |
| CO₂ range | 0-2000 ppm |
| Time resolution | from 1 s; standard delivery setting for emissions measurements is 2 s and can be changed in the Web UI |
| NO₂ detection limit in the 2026 catalogue, 2σ | 0.09 ppb at 60 s |
| NO₂ precision in the 2026 catalogue, 1σ | 0.40 ppb at 1 s and 0.05 ppb at 60 s |
| Additional values from the model table | |
| NO₂ detection limit, 2σ | 350, 100 and 30 ppt at 2, 30 and 300 s respectively |
| NO₂ precision, 1σ | 175, 50 and 15 ppt at 2, 30 and 300 s respectively |
| CO₂ performance | relative precision approximately 2 ppm; accuracy approximately 10 ppm with regular offset calibration; detection limit approximately 4 ppm |
| Response time, 10-90% | 2 s at 1 l/min or 1 s at 2 l/min |
| Zero drift | less than 0.1 ppb/month; automated reference measurements further reduce drift |
| Temperature sensitivity | less than 0.01 ppb/°C for the ICAD path |
| NO₂ spectral range | approximately 430-480 nm |
| Effective optical path | up to 2 km |
| Cross sensitivity | no significant spectroscopic cross sensitivity to H₂O, O₃, carbon oxides, CH₄, HCHO, hydrogen, sulphur compounds, chlorine, ammonia and selected hydrocarbons |
| Sample, conversion and calibration | |
| Sample flow | 1-2 l/min |
| Sample preparation | sample drying is not required; a PFA aerosol-filter holder with a PTFE filter is used in the sampling path |
| NO conversion | internal NOx-free ozone generator; NO is converted to NO₂ in the second path |
| Path-length characterisation | optional helium every 1-2 years or an NO₂ reference measurement; gas-free ICOM method subject to confirmation of availability in the current software version |
| NO₂ calibration | NO₂ calibration gas is not required; concentration is derived using literature absorption data |
| Converter calibration | NO gas above 1000 ppb, approximately every 12 months |
| CO₂ calibration | regular offset calibration; external CO₂ gas is not required in the standard Plume Chasing procedure |
| Consumable gases | no gases required for normal operation |
| Plume Chasing and emission calculation | |
| Calculation method | real-time NOx/CO₂ ratio; result is independent of plume dilution |
| Emission outputs | NOx and NO₂ emission factors in mg/km or mg/kWh |
| Vehicle measurement time | approximately 15 s for preliminary screening; up to 1 min for a valid measurement |
| Vehicle classification | LDV Euro 4, 5, 6 and HDV EURO IV, V, VI |
| Vehicle probe | two inlets merged into one sample line, adjustable width 170-220 cm, additional 5 m PTFE tubing |
| Operating conditions and construction | |
| Operating temperature | -10 to +40°C in the emissions configuration with cooling and heating |
| Thermal stabilisation | air-to-air cooling and heating; measurement-cell temperature stability approximately 0.2°C |
| Start-up time | typically less than 1 min |
| Power and consumption | 12 V DC; typically less than 40 W |
| Mechanical stability | insensitive to ordinary vibration during mobile measurements |
| Weight | less than 10 kg in the current product sheet, depending on configuration |
| Enclosure | 19-inch rack, 3U; 43.8 × 13.2 × 43.5 cm (W × H × D) |
| Mobile variant | ICAD-NOx-210DE-M model in a rugged Ensto field enclosure |
| Control, communication and equipment | |
| Processing unit | embedded computer with analytical, measurement and emission-factor software |
| User interface | Web UI and wireless tablet; system health, traces, validity assessment and emission class |
| Data interfaces | LAN, Wi-Fi, RS232, M2M, OPC UA, Bayern-Hessen protocol; optional voltage and current outputs |
| Data memory | internal memory for up to approximately two years of data |
| Diagnostics | front display, System Health table and checks of gas flow, voltage and temperatures; span adjustment in the Web UI |
| Included equipment | large zero-air cartridge, PFA aerosol-filter holder with a PTFE filter, 5 m PTFE tubing, filter keys and 3 m LAN cable; DE-model cooling |
| Required items | external ACC-PWR-8A power supply and ACC-WIFIUSB Wi-Fi module |
| Options and accessories | operator tablet and vehicle mount, IC-ACC-GPSEXT GPS, IC-ACC-PROBESYS probe, PTFE filters, zero-air system, maintenance set and NOx-path spare parts |
| ICAD patents | EP3329251, DE 10 2015 000 423, US15/748,923 and China ZL201680057099.6 |
The integrated CO₂ channel differentiates the DE model from ICAD-NOx-210D and enables emission-factor determination in a rapidly changing, diluted sample.
We will configure the sampling system, tablet, GPS, vehicle power and reporting for the planned measurement campaign.