AIRYX · ICAD series · mobile NOx/CO₂ emissions

ICAD-NOx-210DE

A dual-cell NO, NO₂ and NOx analyser with an integrated NDIR CO₂ sensor. The DE model measures diluted exhaust plumes and derives real-time NOx/CO₂ emission factors without removing the target vehicle from traffic.

AIRYX ICAD-NOx-210DE analyserICAD-NOx-210DE
4 resultsNO, NO₂, NOx and CO₂ from one system
2 sstandard time setting for emission measurements
15-60 sfrom preliminary screening to a valid vehicle result
<40 Wtypical consumption from a 12 V supply
Real-driving measurements

An emission factor independent of plume dilution

The measurement vehicle follows a selected car and samples its diluted exhaust plume. A CO₂ increase identifies the event, while the NOx/CO₂ ratio accounts for fuel consumption and current engine load.

Plume Chasing step by step

The direct ICAD channel measures NO₂, the second channel detects NO after ozone conversion and the internal NDIR sensor records CO₂. The software identifies the plume, combines the signals and calculates NOx and NO₂ emission factors in mg/km or mg/kWh.

parallel NO, NO₂, NOx and CO₂ measurement
real-time result independent of plume dilution
identification of high-emitting vehicles
LDV Euro 4-6 and HDV EURO IV-VI classification
mobile operation with a tablet and optional GPS
See real-world vehicle emission measurements →
Vehicle-emission measurement by the Plume Chasing method
Measurement path and sampling

Two ICAD cells, a CO₂ sensor and a vehicle probe

The system retains the speed required for short emission events. The sample does not need pre-drying, and the analyser is insensitive to ordinary vibration during mobile operation.

Two ICAD cells and CO2 sensor diagram

Parallel gas analysis

NO₂ is measured directly, NO after conversion to NO₂, and CO₂ by an independent dual-wavelength NDIR sensor.

Dual-inlet Plume Chasing probe on a vehicle bumper

IC-ACC-PROBESYS probe

Two flexible bumper inlets merge through a T-piece into one sample line. The assembly width is adjustable from 170 to 220 cm.

Measurement software

Live plume and emission assessment

A wireless tablet guides the operator through each measurement. The interface shows event validity, CO₂ signal strength, NOx and CO₂ traces, the calculated emission factor and assigned emission class.

From screening to report

A preliminary vehicle screening can take approximately 15 seconds, while a complete valid measurement can take up to one minute. Log files are created automatically for the final campaign report.

wireless operation from the vehicle cockpit
automatic measurement-event validation
position and time synchronisation from optional GPS
internal memory for extended campaigns
AIRYX Plume Chasing interface on a tablet
Instrument technical data

ICAD-NOx-210DE specification

Parameters of the DE instrument and its mobile-emission application configuration.

Analytical performance
Measured componentsNO₂ - direct ICAD spectroscopy; NO - conversion to NO₂; calculated NOx; CO₂ - internal NDIR sensor
Measurement arrangementtwo parallel ICAD cells and a dual-wavelength NDIR CO₂ sensor
NO and NO₂ range0-5000 ppb for each component; custom ranges are available
CO₂ range0-2000 ppm
Time resolutionfrom 1 s; standard delivery setting for emissions measurements is 2 s and can be changed in the Web UI
NO₂ detection limit in the 2026 catalogue, 2σ0.09 ppb at 60 s
NO₂ precision in the 2026 catalogue, 1σ0.40 ppb at 1 s and 0.05 ppb at 60 s
Additional values from the model table
NO₂ detection limit, 2σ350, 100 and 30 ppt at 2, 30 and 300 s respectively
NO₂ precision, 1σ175, 50 and 15 ppt at 2, 30 and 300 s respectively
CO₂ performancerelative precision approximately 2 ppm; accuracy approximately 10 ppm with regular offset calibration; detection limit approximately 4 ppm
Response time, 10-90%2 s at 1 l/min or 1 s at 2 l/min
Zero driftless than 0.1 ppb/month; automated reference measurements further reduce drift
Temperature sensitivityless than 0.01 ppb/°C for the ICAD path
NO₂ spectral rangeapproximately 430-480 nm
Effective optical pathup to 2 km
Cross sensitivityno significant spectroscopic cross sensitivity to H₂O, O₃, carbon oxides, CH₄, HCHO, hydrogen, sulphur compounds, chlorine, ammonia and selected hydrocarbons
Sample, conversion and calibration
Sample flow1-2 l/min
Sample preparationsample drying is not required; a PFA aerosol-filter holder with a PTFE filter is used in the sampling path
NO conversioninternal NOx-free ozone generator; NO is converted to NO₂ in the second path
Path-length characterisationoptional helium every 1-2 years or an NO₂ reference measurement; gas-free ICOM method subject to confirmation of availability in the current software version
NO₂ calibrationNO₂ calibration gas is not required; concentration is derived using literature absorption data
Converter calibrationNO gas above 1000 ppb, approximately every 12 months
CO₂ calibrationregular offset calibration; external CO₂ gas is not required in the standard Plume Chasing procedure
Consumable gasesno gases required for normal operation
Plume Chasing and emission calculation
Calculation methodreal-time NOx/CO₂ ratio; result is independent of plume dilution
Emission outputsNOx and NO₂ emission factors in mg/km or mg/kWh
Vehicle measurement timeapproximately 15 s for preliminary screening; up to 1 min for a valid measurement
Vehicle classificationLDV Euro 4, 5, 6 and HDV EURO IV, V, VI
Vehicle probetwo inlets merged into one sample line, adjustable width 170-220 cm, additional 5 m PTFE tubing
Operating conditions and construction
Operating temperature-10 to +40°C in the emissions configuration with cooling and heating
Thermal stabilisationair-to-air cooling and heating; measurement-cell temperature stability approximately 0.2°C
Start-up timetypically less than 1 min
Power and consumption12 V DC; typically less than 40 W
Mechanical stabilityinsensitive to ordinary vibration during mobile measurements
Weightless than 10 kg in the current product sheet, depending on configuration
Enclosure19-inch rack, 3U; 43.8 × 13.2 × 43.5 cm (W × H × D)
Mobile variantICAD-NOx-210DE-M model in a rugged Ensto field enclosure
Control, communication and equipment
Processing unitembedded computer with analytical, measurement and emission-factor software
User interfaceWeb UI and wireless tablet; system health, traces, validity assessment and emission class
Data interfacesLAN, Wi-Fi, RS232, M2M, OPC UA, Bayern-Hessen protocol; optional voltage and current outputs
Data memoryinternal memory for up to approximately two years of data
Diagnosticsfront display, System Health table and checks of gas flow, voltage and temperatures; span adjustment in the Web UI
Included equipmentlarge zero-air cartridge, PFA aerosol-filter holder with a PTFE filter, 5 m PTFE tubing, filter keys and 3 m LAN cable; DE-model cooling
Required itemsexternal ACC-PWR-8A power supply and ACC-WIFIUSB Wi-Fi module
Options and accessoriesoperator tablet and vehicle mount, IC-ACC-GPSEXT GPS, IC-ACC-PROBESYS probe, PTFE filters, zero-air system, maintenance set and NOx-path spare parts
ICAD patentsEP3329251, DE 10 2015 000 423, US15/748,923 and China ZL201680057099.6
DE-model applications

From road vehicles to vessel emissions

The integrated CO₂ channel differentiates the DE model from ICAD-NOx-210D and enables emission-factor determination in a rapidly changing, diluted sample.

Vehicle Plume Chasingscreening passenger and heavy-duty vehicles for elevated emissions
Real-driving emissionsNOx/CO₂ signatures under changing engine load
Ships and waterwaysplume measurements from a bridge, shoreline or location beside a shipping lane
Point samplingPoints Sampling configurations for assigning emissions to specific sources
Research and authoritiesresearch campaigns, fleet screening and more efficient vehicle inspection

Enquire about ICAD-NOx-210DE