AIRYX OPC-UV3-DL-301
Open Path Ammonia AnalyzerA multi-component Open Path UV-DOAS system for contact-free trace-gas measurement. It analyses NH₃, NO, SO₂, O₃, H₂S, CS₂ and selected VOCs and aromatic compounds in parallel, without sample extraction. Results represent the average concentration across the full optical path, and all measured components are recorded in the output file.
OPC-UV3-DL-301A UV beam instead of sample extraction
Light from a deuterium lamp travels to a retroreflector and back. The DOAS algorithm separates the characteristic gas absorption from scattering, aerosols and intensity variations.
A result representative of the full path
Concentration is averaged across the complete atmospheric path. No probe, pump, filter or heated sampling line is required.
Multi-component measurement. Components are identified by their characteristic absorption spectra and analysed in parallel. With no sample extraction, there are no losses in sampling lines or filters. No calibration gases are required.
Automatic referencing prevents drift, while the method remains robust against lamp ageing, rain, scattering and window losses.

Detectable compounds
Each OPC system analyses all components specified in the current configuration and data sheet, and results for every measured component are recorded in the output file.
| Component | LOD [ppb] | Range [ppb] |
|---|---|---|
| Inorganic / core gases | ||
| NH₃ | 1 | 0–100 000 |
| NO | 2 | 0–5000 |
| SO₂ | 5 | 0–2000 |
| O₃ | 15 | 0–1000 |
| H₂S | 200 | 0–1400 |
| CS₂ | 0.2 | 0–35 |
| VOCs / aromatic and organic compounds | ||
| Toluene | 20 | 0–6000 |
| Styrene | 5 | 0–170 |
| Benzene | 15 | 0–26 000 |
| Chlorobenzene | 12 | 0–4400 |
| m-Xylene | 20 | 0–9000 |
| p-Xylene | 8 | 0–3700 |
| m-Cresol | 4 | 0–9000 |
| p-Cresol | 1 | 0–900 |
| o-Cresol | 6 | 0–1800 |
| Benzaldehyde | 3 | 0–1600 |
| Ethylamine | 10 | 0–3200 |
| Methylfurane | 8 | 0–350 |
One analyser, several measurement directions
The motorised telescope routes the beam between retroreflectors. The camera and searchlight support path identification, automatic and remote alignment, and position correction without manual field aiming.


Complete OPC-UV3-DL-301 specifications
Parameters follow the current technical data sheet supplied for the instrument.
| Measurement performance | |
|---|---|
| Detectable gases | NH₃, NO, SO₂, O₃, H₂S, CS₂ and the VOCs and aromatic compounds listed in the component table |
| Detection limits and ranges (v2.4) | 18 components; full values are listed in the ‘Measurable components’ section above. |
| Time resolution | up to 1 minute |
| Reference conditions | LOD depends on the path configuration and visibility; values refer to a 100 m distance between telescope and reflector. Ranges: optical density of 1 at 25 m; other ranges available on request. |
| Optics | |
| Light source | deuterium lamp; lifetime over 3 months, typically 6 months |
| Telescope | mirror telescope; 300 mm focal length |
| Spectrometer | 190–310 nm; resolution <0.5 nm FWHM; temperature stabilised |
| Distance to reflector | 20–150 m |
| Construction and maintenance | |
| Weatherproofing | IP64; internal heating; dew-point monitoring; window wiper; suitable for outdoor installation |
| Installation | stationary or mobile on an optional tripod; multiple light paths supported |
| Routine maintenance | lamp replacement 2–3 times per year; desiccant replacement twice per year; site-dependent cleaning of window, retroreflector and heat-sink filter |
| Consumables | no other consumables besides lamp and desiccant |
| Motorisation | azimuth 0–360°; elevation −40–75° |
| Temperature control | two-stage heating and cooling of spectrometer and housing |
| Smart setup | integrated camera and searchlight; automatic and remote light-path alignment |
| Additional sensors | ambient temperature and pressure; internal dew point |
| Control and communication | |
| Control unit | embedded PC with Windows 11 IoT; measurement control and analysis run on the instrument’s internal PC |
| Data interfaces | internal data storage; LAN; Wi‑Fi; M2M communication and UIDEP protocol support |
| Result recording | Results for all analysed components are recorded in an output file in the instrument’s internal storage. |
| Power supply and consumption | 24 V; 80 W max. |
Field-campaign evidence
AIRYX materials show a one-year campaign at Neuglobsow with over 90% data coverage and comparisons of NH₃ measurements against established methods.


From farms to facility fence lines
Multi-component Open Path measurement supports air-quality monitoring, agricultural and industrial emissions monitoring, process control and analysis of the spatial distribution of trace gases. H₂S can be included in industrial and facility-boundary (fence-line) monitoring.
Configure the OPC-UV3-DL-301
We will select paths, retroreflectors, tripod or fixed mounting, power supply and analytical ranges.