AIRYX · Hybrid Open Path / MAX-DOAS

AIRYX OPC-VIS-LED-300

Hybrid Open Path DOAS Instrument

One system combines active long-path NO₂ and glyoxal measurement near the surface with passive MAX-DOAS profiling of trace gases and aerosols.

Complete AIRYX OPC-VIS-LED-300 system with Open Path telescope and reflectorOPC-VIS-LED-300
✓
2 ppbNO₂ LOD at a telescope–reflector distance of 500 m
✓
450 nmhigh-power LED
✓
<0.5 nmFWHM spectral resolution
✓
360°azimuth travel
Two modes

Surface concentration and atmospheric profile

The motorised telescope automatically points towards one or more reflectors or selected sky-viewing directions.

Active Open Path

NO₂ and glyoxal

A 450 nm LED and retroreflector form a defined optical path. The result is averaged over the complete path without sample extraction.

DOAS measurement does not require calibration gases. Automatic zero referencing prevents measurement drift without conventional gas calibration.

  • NO₂ and glyoxal LOD: 2 ppb at a telescope–reflector distance of 500 m
  • optional multi-path measurement
  • no tubing or filter losses
Passive MAX-DOAS

Gases and aerosols

Scattered-sunlight spectra provide vertical gas profiles and AOD derived from O₄ absorption.

  • multiple species from one spectrum
  • satellite validation
  • spatial-distribution studies
Measured components

Scope depends on measurement mode

NO₂ and glyoxal are measured actively. The remaining species and aerosols apply to passive MAX-DOAS operation.

NO₂Open Path and MAX-DOAS
CHOCHOglyoxal · both modes
SO₂MAX-DOAS
HCHOMAX-DOAS
BrOMAX-DOAS
H₂OMAX-DOAS
O₄aerosol profiling
HONOMAX-DOAS
IOMAX-DOAS
O₃MAX-DOAS
OClOMAX-DOAS
AODaerosol optical depth
Smart setup

Multiple paths without manual aiming

An integrated camera and searchlight support optical-path identification. Motorisation covers 0–360° azimuth and −40–75° elevation.

Multiple reflectors enable industrial fence-line monitoring or tomographic concentration mapping.

AIRYX Open Path field installation with multiple paths
Technical data

OPC-VIS-LED-300 specifications

Detection limits depend on path length, visibility and integration time.

Data quality
Open Path speciesNO₂, glyoxal
LOD at a telescope–reflector distance of 500 mNO₂: 2 ppb; glyoxal: 2 ppb
MAX-DOAS speciesNO₂, SO₂, HCHO, BrO, H₂O, O₄, HONO, IO, glyoxal; additionally O₃ and OClO according to the manufacturer product page
Time resolutionup to 5 s
Optics
Light sourcehigh-power LED, 450 nm peak
TelescopeUV lens telescope, 300 mm focal length
Spectrometer300–550 nm range; <0.5 nm FWHM resolution; temperature stabilised
Distance to reflector50–1,000 m
Construction and control
Weather protectionIP64, dew-point monitoring and window wiper; suitable for outdoor installation
Motorisationazimuth 0–360°; elevation −40–75°
Temperature controltwo-stage stabilisation of spectrometer and housing
Smart setupintegrated camera and searchlight for optical-path identification
Additional sensorsambient temperature and pressure; internal dew point
Control unitembedded PC, Windows 11 IoT
Interfacesinternal data storage, LAN, Wi‑Fi and UIDEP protocol support
Power12 V; 50 W maximum
MAX-DOAS speciesSlant-column LODSurface-concentration LOD
NO₂4 × 10¹⁴ molec. cm⁻²16 pptv
SO₂4 × 10¹⁵ molec. cm⁻²160 pptv
HCHO3 × 10¹⁵ molec. cm⁻²120 pptv
BrO1 × 10¹³ molec. cm⁻²0.4 pptv
H₂O5 × 10²¹ molec. cm⁻²0.02%
O₄1 × 10⁴¹ molec.² cm⁻⁵—
HONO2 × 10¹⁴ molec. cm⁻²8 pptv
IO5 × 10¹² molec. cm⁻²0.2 pptv
Glyoxal2 × 10¹⁴ molec. cm⁻²8 pptv
Applications

From fence line to boundary-layer profile

The hybrid design reduces the number of instruments needed for parallel near-surface and vertical monitoring.

Air qualitylong-term gas and aerosol monitoring
Traffic emissionsroads, ports and transport corridors
Fence-lineindustrial and agricultural sites
Process controloversight of diffuse and area emissions
Satellite validationMAX-DOAS gas profiles and columns
Tomographyspatial analysis with multiple reflectors
Solution selection

Configure the OPC-VIS-LED-300

We will select path length and number, reflectors, mounting, power and the MAX-DOAS analysis scope.

AIRYXMES-EKOinstrument and measurement-system selectionmeseko@meseko.pl