AIRYX · SkySpec · two-axis MAX-DOAS imaging

SkySpec 2D

A modular system with a two-axis telescope that automatically points anywhere in the sky hemisphere. It supports scattered skylight, direct-sun observations and trace-gas imaging with one or two UV/VIS channels.

AIRYX SkySpec 2D v.260 telescope in the fieldSKYSPEC 2D
2 axesautomatic elevation and azimuth drives
200 nm–2 µmfused-silica telescope optics range
< 2 mincomplete-system start-up time
IP64telescope and SpecBox for demanding conditions
Measurement principle

Scattered light, direct sun and 2D scanning

SkySpec 2D records spectra in arbitrary directions across the sky hemisphere and below the horizon. DOAS analysis provides gas columns, vertical profiles and two-dimensional maps of emission plumes.

Automatic pointing in any direction

Elevation and azimuth drives move the telescope across a programmed grid, while the optional diffuser switches within seconds between scattered-light and direct-sun measurement.

two motorised axes: elevation and azimuth
inclinometer and real-time position correction
narrow field of view below 0.3° × 1°
automatic sun-search and azimuth calibration routine
optional plume imaging and overlay on a camera panorama
Complete SkySpec 2D system with telescope, SpecBox and computer
System architecture

2D telescope and configurable SpecBox

The separated architecture supports either one broadband spectrometer or two optimised UV and VIS channels, together with a suitable optical-fibre design and length.

AIRYX SkySpec 2D architecture

Stable optics for long campaigns

The fibre cross-section is transformed from circular to slit-shaped, improving throughput and providing uniform spectrometer illumination.

active spectrometer temperature stabilisation
low stray light and high spectral sampling
prism deflector limiting polarisation errors
telescope heating activated below 5°C
optional diffuser, shutter and Hg lamp for direct-sun measurements
Measured components

Trace gases and aerosol properties

The available components depend on the spectrometer, detector, filter and Evaluation-package configuration.

NO₂nitrogen dioxide
O₃ozone
SO₂sulphur dioxide
HCHOformaldehyde
H₂Owater vapour
HONOnitrous acid
BrObromine monoxide
IOiodine monoxide
CHOCHOglyoxal
O₄oxygen collision complex
AODaerosol optical depth
Spectrometer configurations

One channel or a complete UV/VIS system

SkySpec 2D can use one 300–460 nm channel or two spectrometers optimised for UV and VIS.

SKY-SBOX-1S-RGD / HGD

One spectrometer

A compact configuration typically covering 300–460 nm.

  • RGD CMOS or HGD back-thinned CCD
  • resolution below 0.7 nm FWHM
  • SpecBox weight approximately 8 kg
SKY-SBOX-2S-MGD / RGD / HGD

Two UV/VIS spectrometers

Two stabilised channels for broader coverage and optimised sensitivity.

  • UV: 300–408 nm, below 0.5 nm FWHM
  • VIS: 408–553 nm, below 0.6 nm FWHM
  • mixed HGD UV + RGD VIS option
Technical data

SkySpec 2D v.260 specifications

System, telescope, spectrometer and optical-connection parameters consolidated from AIRYX product sheets and the v1.23 overview.

Spectrometers and measurement
Methodpassive UV/VIS DOAS remote sensing: MAX-DOAS, 2D scanning, imaging and direct-sun observations
UV-I configuration300–408 nm; resolution below 0.5 nm FWHM; BG3 filter
VIS configuration408–553 nm; resolution below 0.6 nm FWHM; BG40 filter
UV-II configuration300–460 nm; resolution below 0.7 nm FWHM; BG3 filter; replaces UV-I
Number of spectrometersup to two; single- and dual-channel configurations available
Noisebelow 3 × 10−4 at 103 scans, approximately 60 s integration
Spectral samplingmore than 6 points across the FWHM of the slit function
Quantum efficiencyUV above 50% with a back-thinned detector; VIS up to 80%
Spectrometer temperature20°C, adjustable; stability better than ±0.03°C
Wavelength calibrationfactory calibration; typical shift below 0.01 nm; optional integrated or handheld Hg lamp
Characterisationwavelength calibration, offset, dark-current spectra and detector non-linearity function
Telescope and geometry
Telescope spectral range200 nm–2 µm with fused-silica optical components; custom configurations available
Drivetwo motorised axes: elevation and azimuth; automatic pointing anywhere in the sky hemisphere
Elevation range−10° to 190°; setting resolution 0.1°
Elevation accuracybelow 0.2° (1σ), automatic inclinometer correction
Azimuth range−5° to 185°; 0.1° resolution; virtual 360° coverage due to the elevation range above 180°. The telescope sheet specifies ±0.2° accuracy, while the complete-system sheet states ±2°; confirm for the selected configuration.
FOV, FWHMscattered light: below 0.3° × 1°; direct sun with diffuser: approximately 10° × 10°
Telescope optics75 mm internal focal length; external focus at infinity at 400 nm; 22.5 mm clear aperture; f/4
Heatingautomatic activation below 5°C
Cameraone or two optional 120° × 90° cameras; two cover the full sky and support DSCD overlays on a panorama
Direct sunoptional motorised diffuser/attenuator for radiation homogenisation and attenuation, also enabling automatic dark spectra
Operating conditions and construction
Operating temperatureSpecBox −10 to +40°C; telescope −30 to +50°C
EnclosuresIP64; resistant to UV, dust, water and demanding outdoor conditions
Sensorstemperature ±1°C; pressure ±0.5%; relative humidity ±3%
SpecBox weightapproximately 8 kg
Telescope weightapproximately 7 kg
Complete-system weightapproximately 20 kg including laptop, fibres and cables
SpecBox dimensions40 × 30 × 13.2 cm
Telescope dimensionshousing 20 × 20 × 29 cm; tube length approximately 12.5 cm
Connections, control and power
Optical fibre10 m as standard in the current overview; 15 or 20 m options and extensions; different cross-sections and connectors
CommunicationSpecBox USB 2.0; telescope control via RS232 (SUB-D 9) with USB adapter; analogue camera with USB video grabber
SoftwareSKY-SOFT-STD for elevation and horizon scans, zenith observations, direct-sun measurements and calibration; SKY-SOFT-IMG for imaging; Evaluation packages for dSCD, VCD, NSC and 2D maps
System start-upbelow 2 min
Power12 V DC; complete-system consumption typically below 30 W, maximum 100 W
Stand-alone telescoperequires ACC-PWR-8A and SKY-SOFT-TELE; start-up below 10 s; typically below 2 W, maximum 20 W with heating; optional heated azimuth motor
Equipment and configuration
Required componentsSKY-TELE-2D telescope, selected SKY-SBOX-* SpecBox, SKY-SOFT-STD or SKY-SOFT-IMG, measurement computer and ACC-PWR-8A power supply
Field calibrationoptional SKY-CON-TDIFF diffuser/shutter or SKY-CON-THGDIFF version with integrated Hg lamp; handheld lamp also available
Mountingtripod, wall bracket, mast or rail; tripod 0.91–1.69 m, weight 3.4 kg
Supportspare-parts and maintenance kits, installation, configuration and online support

Direct-sun measurement requires the optional diffuser. Gas imaging requires SKY-SOFT-IMG and SKY-EVAL-IMG software plus angular calibration of the camera against the telescope optics.

System equipment

SpecBox, optics and field calibration

The modular architecture allows the system to be built around the required spectral range, installation site and measurement schedule.

AIRYX SkySpec 2D telescope optomechanics

2D optics and drives

A rotating prism, tilt sensor and drives enable fast sky-hemisphere scanning.

  • automatic elevation correction
  • sun-search routine
  • optional heated azimuth motor
AIRYX SkySpec 2D telescope dimensions

Direct sun and imaging

The optional diffuser changes measurement geometry and can also work as a shutter.

  • one or two wide-angle cameras
  • Hg lamp for calibration monitoring
  • Imaging package with DSCD panorama overlays
Applications

Scanning, direct sun and plume imaging

SkySpec 2D is designed for tasks requiring free selection of the viewing direction, direct-sun observations or spatial mapping of emission plumes.

Air qualityregional and urban observations of trace gases and aerosols
Gas imaging2D plume maps for plants, stacks, volcanoes and emission areas
Satellite validationrepresentative ground-based data for Earth-observation products
Point sourcesremote observation of plumes from industrial plants, power stations and volcanoes
Direct suntotal atmospheric columns from direct observations of the Sun
Special researchsurface reflection, plant fluorescence and moving platforms
Leak detectionlocating leaks and spatially imaging point and area sources
Solution selection

Let us configure SkySpec 2D

We will select the telescope, number of spectrometers, detectors, spectral ranges, optical fibre, computer and software for the planned campaign.

AIRYXMES-EKOinstrument and measurement-system selectionmeseko@meseko.pl