AIRYX · SkySpec · mobile passive remote sensing

SkySpec Mini

A lightweight telescope-spectrometer system that records scattered-skylight spectra for UV/VIS DOAS remote sensing of trace gases and aerosols. Its 12 V supply, USB communication and fast start-up support measurements on mobile platforms and at remote sites with limited infrastructure.

AIRYX SkySpec Mini v.260 systemSKYSPEC MINI
< 0.7 nmstandard FWHM spectral resolution
0.2°pointing accuracy in the 2026 AIRYX product overview
< 2 mininstrument start-up time
< 30 Wtypical power consumption at 12 V
Passive remote sensing

Analysis of scattered skylight

SkySpec Mini points its field of view at programmable elevation angles. Characteristic spectral absorption structures enable DOAS retrieval of light-path gas abundances and aerosol parameters without extracting a sample.

Automatic MAX-DOAS geometry

A motor rotates the prism inside the quartz tube, avoiding external moving parts. The integrated inclination sensor can correct the elevation on a vehicle, ship or in changing field conditions.

motorised elevation from -10° to 190° with fixed azimuth
narrow field of view below 0.3° × 1°
real-time pointing correction from the inclination sensor
optical fibre for homogeneous slit illumination
prism arrangement that limits polarisation-induced bias
SkySpec Mini scattered-skylight observation principle
Instrument architecture

Telescope and spectrometer in one enclosure

Mini combines optics, drive, temperature-stabilised spectrometer and control electronics. Acquisition uses an external computer connected to the instrument through USB.

Internal architecture of the AIRYX SkySpec Mini

Stable field operation

The quartz tube protects the optics and is easy to clean. Heating activated below 5°C helps prevent condensation, snow, ice and freezing of mechanical parts.

actively temperature-stabilised spectrometer
individual factory adjustment and characterisation
low-straylight optical design
UV-resistant, weatherproof IP64 enclosure
optional wide-angle camera for viewing-condition monitoring
Measured components

Trace gases and aerosol parameters

The final output set and sensitivity depend on spectral range, detector grade, measurement geometry and analysis configuration. The spectrometer range can be customised for the application.

NO₂nitrogen dioxide
O₃ozone
SO₂sulphur dioxide
HCHOformaldehyde
H₂Owater vapour
HONOnitrous acid
CHOCHOglyoxal
BrObromine monoxide
IOiodine monoxide
O₄oxygen collision complex
AODaerosol optical depth

O₄ supports light-path and aerosol-property evaluation and is not presented as an independent trace-gas concentration.

Detector selection

SkySpec Mini RGD or HGD

Both variants use the same mechanical platform. Detector selection should follow the required spectral range and target components.

SKY-MINI-RGD

Regular Grade Detector

A cost-efficient CMOS configuration for components absorbing more strongly in the visible region.

  • recommended particularly for NO₂, H₂O, IO and CHOCHO
  • high spectral sampling above 6 px/FWHM
  • active spectrometer temperature stabilisation
SKY-MINI-HGD

High Grade Detector

A back-thinned CCD increases photon yield and measurement sensitivity in the UV.

  • recommended particularly for O₃, SO₂, HONO, HCHO and BrO
  • UV quantum efficiency above 50%
  • more than twice the photon yield of a regular CMOS detector
Complete instrument data

SkySpec Mini v.260 specifications

These parameters describe the configuration in the v.260 model datasheet. Spectral range, filter and detector can be customised within limits that preserve valid spectroscopic analysis.

Spectrometer and spectral performance
Methodpassive UV/VIS DOAS remote sensing of trace gases and aerosols, including MAX-DOAS sequences
Wavelength range300-460 nm standard according to AIRYX product overview v1.23; custom configurations available
Spectral resolutionbelow 0.7 nm FWHM as standard
Optical filterSchott BG3 or BG40 as standard, depending on configuration
Noisebelow 3 × 10-4 at 103 scans, approximately 60 s integration time
Spectral samplingmore than 6 points across slit-function FWHM
Quantum efficiencyabove 50% in the UV for the HGD back-thinned CCD
Spectrometer temperature20°C, adjustable
Temperature stabilitybetter than ±0.03°C
Wavelength calibrationstable in-house calibration with typical shifts below 0.01 nm; manual recalibration possible with a mercury Hg lamp
Factory characterisationwavelength calibration, offset and dark-current spectra, and detector non-linearity function
Telescope and viewing geometry
Drivemotorised elevation axis, fixed azimuth
Elevation range-10° to 190°
Elevation correctionautomatic real-time inclination-sensor correction; 0.2° pointing accuracy
Field of view FWHMbelow 0.3° × 1°, vertical × horizontal
Telescope heatingautomatic activation below 5°C
Cameraoptional; maximum one integrated wide-FOV camera; standard field of view approximately 130° × 90°, customisable on request
Operating conditions, sensors and enclosure
Operating temperature-10 to +40°C; direct sunlight can raise enclosure temperature above this range
Mechanical stabilityIP64 enclosure, sun roof, robust design and simple mounting
Internal temperaturestelescope, spectrometer and electronics temperature measurement with 1°C accuracy
Pressureambient pressure sensor, 0.5% accuracy
Humiditysensor inside the instrument, ±3% relative-humidity accuracy
GPSintegrated
Weightapproximately 7 kg
Enclosure dimensions30 × 20 × 13.2 cm, excluding optical tube
Quartz tubeapproximately 12.5 cm long; 8 cm diameter
Control, communication and power
Measurement computerexternal Windows 10 Professional computer, available as an option
Measurement softwareincluded; configurable angle routines and time resolution
CommunicationUSB; 2 m cable with IP67 field connector
Start-up timebelow 2 min
Power supply12 V DC
Power consumptiontypically below 30 W; maximum 100 W
Mobile poweroptional 50 Ah / 13.6 V LiPo battery in a Peli case or vehicle power
Configuration and accessories
Detector variantsRegular Grade CMOS (RGD) or High Grade back-thinned CCD (HGD)
Required configurationSKY-SOFT-STD control and acquisition software plus an external power supply
SKY-ACC-TRIPODheight 0.91-1.69 m; leg spacing 0.80-1.35 m; weight 3.4 kg; transport length 1.06 m
Mounting optionsfield tripod, rail and mast adapters, and custom mounting elements
Optical optionshandheld mercury Hg lamp, wide-angle camera, custom spectrometer range and filters
Evaluation softwarepackages for spectral analysis, post-processing and data visualisation
Service optionsspare-parts set, maintenance set, online installation and support

The current AIRYX product overview v1.23 dated 16 January 2026 specifies a 300-460 nm standard range, 0.2° pointing accuracy, integrated GPS and an approximate weight of 7 kg. The older v.260 model datasheet contains different values, so the final configuration is confirmed during system selection.

Field configuration

A mobile kit for operation away from stations

Low weight and power demand support a complete station with tripod, computer and battery. Rail and mast adapters are also available.

SkySpec Mini on a tripod with mobile battery

Tripod and battery

A 50 Ah / 13.6 V LiPo battery in a Peli case powers the instrument at sites without mains access.

  • tripod and multiple mounting adapters
  • 12 V power from battery or vehicle
  • field kit for mobile campaigns
SkySpec Mini with external measurement computer

Computer and software

An external notebook or desktop controls the measurement sequence and records spectra through USB.

  • SKY-SOFT-STD acquisition software
  • optional spectral-evaluation packages
  • camera, Hg lamp and maintenance sets
Instrument dimensions

Small enclosure with complete optics

The optical tube, connectors and mounting plate must be included when planning installation on a tripod, vehicle or mast.

instrument enclosure 300 × 200 × 132 mm
overall width with external elements approximately 330 mm
optical tube 123 mm long and 80 mm in diameter
complete instrument weight approximately 7 kg
AIRYX SkySpec Mini dimensions
Dimension views of SkySpec Mini; values are shown in millimetres.
Model applications

Mobile monitoring of the atmosphere and emission sources

SkySpec Mini is suited to work where small size, battery power, fast deployment and automatic viewing-angle correction are priorities.

Air-quality monitoringpassive observation of trace gases and tropospheric change
Vertical profilesMAX-DOAS angle sequences and external profile inversion
Point sourcesremote observation of plumes from plants, stacks, ports and volcanoes
Mobile platformsmeasurements from vehicles, ships and frequently relocated sites
Field campaignsoperation at remote locations with limited infrastructure
Atmospheric researchgas columns, aerosol properties and observation-data validation

Ask about SkySpec Mini

We will select the RGD or HGD variant, spectral range, computer, software, power supply and field accessories for your campaign.

Contact MES-EKO