WGA020
Wastewater Gas AnalyserA complete system for long-term monitoring of greenhouse-gas emissions from biological wastewater treatment. It measures N₂O, CH₄, CO₂ and O₂ in real time above aerated basins and automatically calculates net greenhouse-gas emission fluxes.
WGA020
Emission measurement, not just concentration
The WGA020 measures sample-gas concentrations, background concentrations and gas flow, allowing it to calculate net greenhouse-gas emission fluxes automatically, relative to the sampling area.
From the wastewater surface to a net-emission result
The system also records:
- ambient temperature,
- atmospheric pressure,
- sample flow measured by an internal sensor,
- system-health parameters.
Time resolution is 1 s internally, with results averaged to 60 s.
Four gases, one process view
Simultaneous greenhouse-gas and oxygen measurements relate emissions to aeration conditions and biological changes in the basin.
Stable performance in wastewater conditions
The system addresses the principal challenges of humid-gas measurement above wastewater: condensation, drift, CO₂ interference and changing ambient temperature.
| Gas | Range | LOD (3σ) | Emission-rate sensitivity (σ) |
|---|---|---|---|
| N₂O | 0–1,000 ppm | 0.5 ppm | 0.3 mg/m²/h |
| CO₂ | 0–10 vol.% | 40 ppm | 24 mg/m²/h |
| CH₄ | 0–1,000 ppm | 5 ppm | 1.1 mg/m²/h |
| O₂ | 0–100 vol.% | 0.1 vol.% absolute or 0.5% of reading | n/a |
The WGA020 is a low-maintenance system. Automatic internal corrections do not replace external sensor calibration, which is performed manually once a year using standard gases.
Typical servicing takes place every 6–12 months. Annual maintenance includes sensor calibration, scrubber refill or filter replacement, and sampling-hood cleaning.
Floating sampling hood
The stainless-steel hood floats on the tank surface and follows dynamic water-level changes, providing stable gas collection above the biological basin. Its sampling area is approximately 0.3 m². Sampling-line length and construction are selected for the site.
Installation requirements
The sampling-hood location and system arrangement are selected for the basin geometry, railing layout, sampling-line route and available utilities. Installation requires prior verification of site conditions.
Complete WGA020 specification
Parameters from the complete AIRYX WGA020 data sheet, issued 27 April 2026.
| Measurement and calculations | |
|---|---|
| Measured gases | N₂O, CO₂, CH₄, O₂ |
| Measurement principle | NDIR for N₂O, CO₂ and CH₄; electrochemical sensor for O₂; automatic cross-interference correction and sample-air drying |
| Measured parameters | Sample and background concentrations, total sample flow, greenhouse-gas net-emission fluxes, ambient temperature and pressure, and system-health parameters |
| Time resolution | 1 s internal; 60 s averages |
| Total sample flow | 0–20 slm |
| Analysed sample flow | approximately 0.2 slm |
| Background-air flow | 0.3–0.5 slm |
| Automatic internal corrections | Internal CO₂ cross-interference correction and automatic zero-drift correction |
| External calibration | Annual manual sensor calibration using external standard gases |
| Operating conditions and construction | |
| Operating temperature | −10°C to +40°C |
| Ambient pressure | 800–1,150 hPa |
| Enclosure | Rugged, weatherproof design; IP64 |
| Power supply | 220/230 V AC; the supply appropriate to the ordered configuration is confirmed in the quotation |
| Analyser power consumption | 80 W nominal; 120 W peak |
| Sampling-line heating | 0–156 W depending on temperature and length; typically 80 W at 10°C with a 5 m heated line |
| Dimensions | Mounting rack: 1,540 × 500 × 340 mm; sampling hood: 890 × 760 × 240 mm |
| Weight | Rack including instrument and heating unit: approximately 35 kg; sampling hood: approximately 8 kg; additional equipment: approximately 5 kg |
| Sampling | |
| Sampling area | Approximately 0.3 m²; optional 2 × 0.3 m² |
| Sampling line | 3–7 m, typically 5 m; 25 mm outer diameter or 75 mm for the heated line |
| Background air | Pressurised air is preferred; alternatively, ambient air from a suitably selected reference location |
| Control and data | |
| User interface | Touch display; web interface from a connected PC or over the internet |
| Data interfaces | Ethernet; USB data export; optional remote VPN access through an internal LTE modem |
| Data format | UTF-8 text files |
| Service | Service typically every 6–12 months; annual sensor calibration, scrubber or filter servicing and sampling-hood cleaning |
Dynamics that periodic sampling cannot reveal
High time resolution reveals daily peaks and short emission episodes. This is especially important for N₂O, whose climate impact is substantial even when concentration changes are small.
From emission inventories to process control
The WGA020 supplies data for climate reporting, aeration optimisation and research into biological process dynamics.
Configure the WGA020 for your treatment plant
We will define the mounting location, number of hoods, sampling line length and heating, background-air source, power, communications, commissioning and periodic service scope.