Ammonia analysers NH₃

Continuous selective ammonia measurement in ambient air, at facility boundaries, livestock sites, industrial processes and technical gases.

NH₃ requires the right sampling approach

Ammonia is reactive and readily interacts with surfaces and moisture. Reliable results therefore depend not only on the detector but also on tubing material and length, line temperature, filtration and sample transport time. In some applications, contact-free Open Path measurement is preferable because it averages concentration along an optical path. Other tasks call for a highly selective extractive analyser.

Agriculture and livestock

NH₃ monitoring inside buildings, around farms and in emission studies.

Industry and emissions

Process control, gas-cleaning installations and facility-boundary monitoring.

Research and air quality

Low-level measurements in field campaigns and laboratories.

Point measurement or Open Path?

An extractive system measures a sample from a defined point and can combine NH₃ with other components. Open Path determines an average concentration along the beam without transporting reactive gas through tubing. Photoacoustic spectroscopy and optical DOAS methods can provide selectivity and low detection limits, but the configuration must match the expected range and environment.

NH₃ level and required detection limit
Point, area or facility-boundary measurement
Sample-line length and temperature
Humidity, dust and potential interferences

Selected instruments

Examples from the MES-EKO range. Final selection is confirmed after reviewing the range and sample conditions.

Related solutions

Open guides for the application, process or a related component.

Frequently asked questions

Short answers before selecting a configuration.

Why is NH₃ measurement difficult?

Ammonia can adsorb on sample-path surfaces and interact with moisture. Unsuitable tubing or long transport times degrade response and concentration recovery.

When is Open Path a good choice?

When contact-free averaging over a larger area is needed, for example around a farm, at a facility fence line or above a diffuse source.

Discuss your measurement with MES-EKO

Send the gas, expected range, sample conditions and operating mode. We will select the method, analyser and required system equipment.

Send an enquiry

NH₃ in agriculture and livestock

Select point or Open Path measurement for livestock buildings, farm boundaries and emission studies.

Agricultural ammonia monitoring

NH₃ measurement: point or Open Path?

Compare point results with path averages and the effects of tubing and diffuse sources.

Read guide