GASERA ONE
The high-performance configurable GASERA platform combines cantilever-enhanced photoacoustic detection with an application-specific combination of lasers and/or infrared light sources.
Browse the complete range and filter instruments by manufacturer, measurement task, gas, model or application.
Need a different configuration? Ask MES-EKO →
The high-performance configurable GASERA platform combines cantilever-enhanced photoacoustic detection with an application-specific combination of lasers and/or infrared light sources.
A configurable multi-gas analyser combining cantilever-enhanced photoacoustic detection with selectable infrared light sources. It is designed for selective, simultaneous trace-gas measurements and continuous unattended operation.
A dedicated photoacoustic analyser providing ppb-level sensitivity for reliable measurement of ambient greenhouse-gas concentrations.
A selective trace-level HF analyser developed for reliable monitoring of airborne molecular contamination and rapid detection of hydrogen fluoride releases.
A selective analyser for continuous monitoring of low formaldehyde concentrations. The QCL-based photoacoustic system reliably measures ambient background levels.
The analyser combines cantilever-enhanced photoacoustic detection with a quantum cascade laser to detect very small CF₄ releases with high stability.
An open photoacoustic detector platform for use with modulated laser sources. Its optical cantilever microphone provides high sensitivity in a compact sample cell.
A selective photoacoustic analyser configuration for continuous trace-level measurement of hydrogen chloride in air and process applications.
A direct analyser for simultaneous evaporative-emission measurements inside a SHED chamber, avoiding impinger benches and remote laboratory analysis.
An ultra-high-performance FTIR accessory for rapid analysis of solid, semi-solid and liquid samples, often without sample preparation.
An automatic sampling unit for sequential measurements from multiple lines or sample bags with GASERA ONE analysers.
A compact cantilever-enhanced photoacoustic platform intended for mechanical, pneumatic and software integration into customer-developed instruments.
A fast online analyser for high methane concentrations. TDLAS provides selective measurements without cross-sensitivity from the remaining gas matrix.
A plug-and-play online system for reliable biogas, digester-gas and landfill-gas quality measurements and process control.
A portable analyser for spot measurements of biogas, digester gas and landfill gas at multiple locations in the field.
A flexible continuous analyser platform using NDIR, electrochemical or zirconium-oxide measurement principles depending on the target component.

BioBasic Biomethane measures CH₄, CO₂, O₂ and H₂S in biomethane after upgrading and at grid injection. Continuous measurement at one-second intervals supports quality monitoring of the upgraded gas.

GA220 Biomethane is a CH₄ and CO₂ analyser for continuous biomethane monitoring after upgrading and at grid injection. Dual-beam NDIR measures every second across CH₄ 90–100 vol.% and CO₂ 0–10 vol.%.

A continuous oxygen analyser with a paramagnetic measuring cell, short response time and high long-term stability.

A precise analyser for one IR-active component where low concentration levels and reliable long-term monitoring are required.
An inline diffusion analyser for rapid threshold monitoring of toxic and explosive gas mixtures directly in the process.

Developed for quick and easy online measurements of up to six process gases where mutual interferences must be compensated and low detection limits are required.
An online NDIR analyser for formaldehyde and other IR-active components in hot, humid gas streams where conventional gas cooling may cause losses.
Enables measurement of up to six IR-active gases where very low detection limits and sophisticated cross-sensitivity compensation are required.
A continuous NDIR analyser for reliable supervision of harmful solvent concentrations in environmentally and safety-critical processes.
Deliberately lowers the dew point of humid gases to protect the measurement system from condensation and stabilise the outlet dew point.
A multi-gas thermal-conductivity analyser for continuous process measurements where components have sufficiently different thermal conductivities.
A compact continuous oxygen analyser using a zirconium-oxide sensor and a PTFE sample-gas path.
A portable oxygen analyser for accurate measurements at changing locations and installation points.
A cost-effective stationary NDIR instrument designed exclusively for monitoring high concentration ranges in solvent-containing gas mixtures.
An inline analyser intended for direct supervision of hazardous gas concentrations in industrial processes.

A certified portable FID analyser for TOC and simultaneous MHC/NMHC determination in stack emissions.

An automatic ATEX micro gas chromatograph for continuous THT or TBM monitoring in fuel-gas distribution networks.

An automatic ATEX microGC for continuous VOC monitoring and activated-carbon filter breakthrough detection in biogas upgrading.

An in-situ analyser for fast, direct and selective NO₂ measurement over a range of up to 5000 ppb.

A dual-cell in-situ analyser for parallel NO and NO₂ measurement and determination of total NOx over a range of up to 5000 ppb.

A mobile Twin Inlet analyser for parallel NO₂ measurement at two independent locations using two ICAD cells.

A High Grade, high-sensitivity NO₂ analyser for atmospheric and clean-background research, with a detection limit down to 15 ppt at 300 s.

A High Grade dual-cell analyser for high-sensitivity NO, NO₂ and NOx measurement, with a 0.03 ppb detection limit at 60 s.

A high-sensitivity analyser for simultaneous, direct HONO and NO₂ measurement without a converter, designed for atmospheric research, air quality studies and mobile field campaigns.

A dual-cell NO, NO₂ and NOx analyser with an integrated CO₂ sensor and software for real-time Plume Chasing emission-factor measurements.

A lightweight telescope-spectrometer with integrated GPS for mobile passive UV/VIS DOAS remote sensing of trace gases and aerosols, controlled from an external computer through USB.

A self-contained telescope-spectrometer system with an embedded computer for mobile passive UV/VIS DOAS remote sensing of trace gases and aerosols.

A modular MAX-DOAS system with a separate 1D telescope and one or two temperature-stabilised spectrometers for long-term atmospheric monitoring.

A modular DOAS system with a two-axis telescope for MAX-DOAS, direct-sun observations and spatial imaging of trace gases and aerosols.

A calibrated and stabilised UV/VIS spectrometer module for integration with telescopes, external optics and custom DOAS systems.

A hybrid active Open Path and passive MAX-DOAS system for NO₂, glyoxal, multiple trace-gas profiles and aerosols.

A contact-free Open Path UV-DOAS analyser for NH₃, NO, SO₂ and selected gases and VOCs across one or several 20–150 m paths.

A modular multi-gas Open Path DOAS system with telescope and LED or LDLS analyser for 100–3,000 m paths.

A complete system for continuous N₂O, CH₄, CO₂ and O₂ measurement above an aeration basin and automatic net emission-flux calculation.

Industrial detector with LCD and 4–20 mA output. Electrochemical, NDIR and catalytic versions selected for one gas and range.

Fixed 4–20 mA detector. Versions for one gas or refrigerant with a selected sensor and measuring range.

Tecnocontrol TS482 addressable gas detectors for CE516P. Compare 21 catalytic and electrochemical versions for flammable gases, toxic gases and oxygen.

Dual-gas detector for car parks and industrial sites. TS455CB monitors CO and petrol vapours. TS455CN2 monitors CO and NO₂.

Fixed explosion-proof detectors for toxic gases, oxygen, flammable gases and CO₂, with linear 4–20 mA output and replaceable cartridges.

Portable flue gas analyzer for boiler adjustment and service measurements. O₂ and CO, plus NO on OCN.

Fixed analysis of flue gas and selected process gases. Ranges, channel combinations and sample conditioning depend on the variant.

The control panel receives signals from gas detectors, displays their readings and controls alarms. It supports 4 detectors as standard and up to 8 with an expansion board.

An analogue 4–20 mA control panel with local and remote inputs. With the appropriate expansion, it supports up to 24 detection points and 25 relay outputs.

A panel for up to 16 compatible addressable detectors on two RS-485 buses. It has five relay outputs as standard, expandable to nine with ES414.

Industrial extractive gas detection. Gas-specific versions, 4–20 mA, flow monitoring and a purge cycle.

Pre-start combustion chamber atmosphere monitoring. Two pre-alarms, burner interlock and gas versions selected by code.

A fixed detector with an integrated sensor and no display. It sends readings to a control panel or monitor via 4–20 mA or Modbus RS-485, depending on the ordered version.

An integrated-sensor detector without a display for refrigeration leak monitoring. Its versions offer analogue and digital outputs and relays, depending on the configuration.

An integrated-sensor detector with an LCD for local concentration readings. It provides operation at the sensing point and sends readings and alarm states to the installation.

A detector without a display, with its sensor installed separately from the main unit. Separating sensing and electronics helps position the detection point while retaining access for operation.

A detector with an LCD and a remote sensor. Readings are viewed at the main unit while the sensor is placed at the required point, up to 3 m from the electronics.

A system monitor displaying readings and alarms from up to four 4–20 mA detectors. Its touchscreen provides a system overview; SM400 does not measure gas itself.

Fixed detector for continuous monitoring of flammable gases and vapours in industrial installations. The GDS850P version uses a replaceable catalytic pellistor cartridge.

Portable detector for personal protection. Each unit is configured for one gas. It warns the wearer using visual, audible and vibration alarms.

The new-generation APNA-380 provides continuous NO, NO₂ and NOₓ measurement using cross-modulation chemiluminescence, with rapid line switching and remote operation.

A modular ultraviolet-fluorescence SO₂ monitor with an integrated HC cutter, remote operation and up to eight selectable ranges.

A cross-modulation NDIR carbon-monoxide monitor with a compensation detector for coexisting gases and fast continuous response.

A cross-modulation NDUV ozone monitor using a UV LED source and an ozone-decomposer reference path for stable continuous measurement.

A continuous non-dispersive infrared analyser for carbon dioxide measurements in ambient air and monitoring networks.

A single-detector FID monitor with selective combustion for simultaneous continuous measurement of methane, non-methane and total hydrocarbons.

A continuous analyser configuration for hydrogen sulphide monitoring using an oxidation converter and UV fluorescence detection.

A continuous ammonia-monitoring configuration using a converter and chemiluminescence analyser.

A continuous particulate monitoring platform designed for stable unattended operation in ambient networks.
A portable automated measuring system combining the PG-350 gas analyser with sample conditioning and system components in a transportable package.

A continuous gas-analysis system configured for industrial emissions measurement and long-term unattended operation.