FRESENIUS · Biomethane quality analyser

BioBasic Biomethane

BioBasic Biomethane measures CH₄, CO₂, O₂ and H₂S in biomethane after upgrading and at grid injection. Continuous measurement at one-second intervals supports quality monitoring of the upgraded gas.

BioBasic BiomethaneBIOBASIC BIOMETHANE
✓
CH₄ / CO₂ / O₂ / H₂Sfour components
✓
1 scontinuous measurement
✓
0–100 ppmH₂S range
✓
IP54wall-mounted housing
✓
0.7–1.1 barpressure compensation
✓
4–20 mAstandard outputs
4measured components
1 smeasurement interval
18 kginstrument weight
IP54wall-mounted enclosure
Fresenius Umwelttechnik

The instrument and its role in the measurement system

BioBasic Biomethane monitors product-gas quality after biogas treatment, directly at the transfer point to the gas network. It combines CH₄, CO₂, O₂ and H₂S measurements to show the main biomethane components as well as oxygen and trace hydrogen sulphide.

Measurements every second quickly reveal quality fluctuations and support adjustments to the upgrading process. The analyser is a process-close complement to the gas chromatograph, whose readings are available every few minutes.

Measurement principles

01

Dual-beam NDIR

Dual-beam infrared absorption measurement for CH₄ and CO₂.

02

Electrochemical O₂ measurement

A galvanic oxygen sensor with temperature compensation from 5 to 45°C.

03

NDUV for H₂S

Optical H₂S measurement with a reference detector, covering 0–100 ppm.

Equipment and integration

✓ CH₄ 90–100 vol.% and CO₂ 0–10 vol.%
✓ O₂ 0–30 vol.% and H₂S 0–100 ppm
✓ Pressure compensation: 0.7–1.1 bar
✓ Internal pump: 4 l/min
✓ Standard 4–20 mA outputs
✓ Optional industrial protocols
Value for the plant

Biomethane quality at the transfer point

Continuous readings help operators respond to changes in gas composition before transfer to the network.

01

After upgrading

CH₄ and CO₂ measurements show product-gas quality after the biogas upgrading stage.

02

At grid injection

O₂ and H₂S channels complement biomethane purity monitoring at the transfer point.

03

Rapid complement to GC

One-second readings show fluctuations between successive results from the process gas chromatograph.

In practice

User benefits

Operation and data transmission are designed for continuous plant monitoring.

✓ One-second measurement — rapid process response
✓ Dual-beam NDIR — high long-term stability
✓ NDUV with a reference detector for H₂S measurement
✓ Automatic calibration with error monitoring
✓ Touch panel and plain-text fault messages
✓ Standard 4–20 mA; optional industrial interfaces
Areas of application

Where is BioBasic Biomethane used?

Gas-quality measurements in biomethane treatment and transfer systems.

✓ Biomethane feed-in systems
✓ Gas-network transfer stations
✓ Biogas upgrading
✓ Power-to-Gas / SNG

Technical specifications

CH₄ / CO₂CH₄: 90–100 vol.%; CO₂: 0–10 vol.%; dual-beam NDIR
O₂0–30 vol.%; electrochemical galvanic sensor
H₂S0–100 ppm; NDUV with reference detector
ResolutionCH₄: 0.1 vol.%; CO₂: 0.01 vol.%; O₂: 0.05 vol.%; H₂S: 0.1 ppm
MeasurementEvery 1 s, continuous
Pressure compensation0.7–1.1 bar
Flow / pumpInternal pump: 4 l/min; optional pump-free version with supply pressure ≥60 mbar
Gas path / connectionsPTFE; CK8/6
Sample and calibration inputs1 sample input, 1 zero-gas input, 1 test-gas input
NDIR/NDUV cell temperatureStabilised at 45°C
Ambient conditions5–45°C; approximately 90% relative humidity; a dehumidified indoor location is recommended
HousingWall-mounted, 400 × 600 × 220 mm; IP54; 18 kg
DisplayMonochrome 128 × 64 pixel, 2.5-inch touch display
Standard interfaceIsolated 4–20 mA outputs
Optional interfacesProfibus DP, Profinet, Ethernet/IP, Modbus TCP
Power supply230 V AC / 50 Hz, 0.9 A, 207 VA; optional 115 V AC / 60 Hz or 230 V AC / 60 Hz

Operation and integration

01

Gas sample

The manufacturer specifies no additional conditioning for dry biomethane. Sample conditions must be considered when selecting the sampling point.

02

Pump or sample pressure

The internal pump provides 4 l/min. The optional pump-free version requires a sample supply pressure of ≥60 mbar.

03

Calibration and integration

Automatic zero/test-gas calibration takes approximately four minutes, during which no measurement results are provided. The calibration interval is configurable.

Ask about configuration

Send your measurement requirements to MES-EKO.