FRESENIUS · Laser methane analyser

Biomethane TDLAS

A fast online analyser for high methane concentrations. TDLAS provides selective measurements without cross-sensitivity from the remaining gas matrix.

Biomethane TDLASBIOMETHANE TDLAS
✓
Optimised for 80–100 vol.% CH₄Biomethane TDLAS
✓
One-second integration timeBiomethane TDLAS
✓
Automatic zero correctionBiomethane TDLAS
✓
Up to eight sample-gas inputsBiomethane TDLAS
✓
Application-specific configurationBiomethane TDLAS
✓
Integration with the complete measurement systemBiomethane TDLAS
CH₄Measured component
0–100 vol.%; optimised for 80–100 vol.%Range
±0.1% of measured valueAccuracy
±0.03 vol.% / 0.01 vol.%Precision / resolution
Instrument overview

The instrument and its role in the measurement system

A fast online analyser for high methane concentrations. TDLAS provides selective measurements without cross-sensitivity from the remaining gas matrix.

A laser analyser for precise supervision of high methane concentrations in biomethane and natural gas. Its selective CH₄ absorption line reduces the influence of accompanying gas components.

Measuring principle

How does Biomethane TDLAS work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

TDLAS — tunable diode-laser absorption

The laser is tuned across a characteristic methane absorption line for fast and selective concentration measurement.

02

Automatic correction

Automatic zero-point and temperature compensation stabilise the result while limiting routine service work.

Equipment and integration

Key features

✓ Optimised for 80–100 vol.% CH₄
✓ One-second integration time
✓ Automatic zero correction
✓ Up to eight sample-gas inputs
✓ Measured component: CH₄
✓ Range: 0–100 vol.%; optimised for 80–100 vol.%
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

Biomethane quality

Precise methane measurement supports quality verification before grid injection.

02

Fast process response

The one-second integration time reveals changes in gas quality quickly.

03

Low maintenance

Selective laser measurement limits cross-sensitivity and calibration effort.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ Optimised for 80–100 vol.% CH₄
✓ One-second integration time
✓ Automatic zero correction
✓ Up to eight sample-gas inputs
✓ Application-specific configuration
✓ Integration with the complete measurement system
Application areas

Where is Biomethane TDLAS used?

♻Biomethane upgrading
✓grid injection
✓natural gas
✓Power-to-Gas
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

Measured componentCH₄
Range0–100 vol.%; optimised for 80–100 vol.%
Accuracy±0.1% of measured value
Precision / resolution±0.03 vol.% / 0.01 vol.%
Integration time1 s
Sample inputs1 standard; expandable to 8
Flow / pressureApprox. 1 l/min; 0.8–1.2 bar, compensated
Housing19-inch rack, 400 mm depth, IP20
InterfacesRS232; optional Profibus DP, Ethernet TCP/IP and Profinet
Precision±0.03 vol.%
Resolution0.01 vol.%
TechnologyTDLAS — tunable diode-laser absorption spectroscopy
Cross-sensitivitiesSelective measurement without influence from the remaining mixture components
Zero-point correctionAutomatic, with patented temperature compensation
Power supply230 VAC / 50 Hz; optional 115 VAC / 60 Hz
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Working range

The highest performance is obtained with the configuration optimised for high CH₄ concentrations.

02

Sample conditions

Pressure, humidity and the composition of accompanying gases must be specified during selection.

03

Integration

Results can be transferred to upgrading-plant and grid-injection control systems.