FRESENIUS · ATEX inline gas detector

ExGard

An inline diffusion analyser for rapid threshold monitoring of toxic and explosive gas mixtures directly in the process.

ExGardExGard
🛡
ATEX Zone 1ExGard
✓
IP68 enclosureExGard
✓
One-second measurement intervalExGard
✓
RS485 / Modbus RTUExGard
🛡
Function: ATEX Zone 1 inline threshold monitorExGard
✓
Principle: Dual-beam NDIRExGard
ATEX Zone 1 inline threshold monitorFunction
Dual-beam NDIRPrinciple
CH₄, CO, O₂, KWL, refrigerants and butane, configuration-dependentComponents
0–100% LEL, 0–5 vol.% or 0–100 vol.%Typical ranges
In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ ATEX Zone 1
✓ IP68 enclosure
✓ One-second measurement interval
✓ RS485 / Modbus RTU
✓ Function: ATEX Zone 1 inline threshold monitor
✓ Principle: Dual-beam NDIR
Application areas

Where is ExGard used?

✓Solvent monitoring
🛡surface treatment and explosion protection
⚙Continuous process monitoring
🏭Environmental and emissions measurements
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

FunctionATEX Zone 1 inline threshold monitor
PrincipleDual-beam NDIR
ComponentsCH₄, CO, O₂, KWL, refrigerants and butane, configuration-dependent
Typical ranges0–100% LEL, 0–5 vol.% or 0–100 vol.%
UncertaintyBelow 1% of measured value and below 0.5% full scale at 100% LEL
Measurement interval1 s
Pressure / minimum flow0.7–1.1 bar; approx. 1 l/min by diffusion
Ambient temperature5–70 °C
Housing / interfacesIP68 ATEX; 4–20 mA and RS485 Modbus RTU
Portfolio noteBrochure-supported earlier/special model; current availability should be confirmed
Resolution0.25% LEL; 0.01 vol.% for the 0–5 vol.% range
Solution selection

Ask about ExGard

Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.

The enquiry will be sent directly to the MES-EKO team.

MES-EKO Sp. z o.o. · Wrocław · (+48) 71 348 64 02 · meseko@meseko.pl