FRESENIUS · CONTINUOUS PROCESS GAS ANALYSER

Gas Analyzer 210

A flexible continuous analyser platform using NDIR, electrochemical or zirconium-oxide measurement principles depending on the target component.

Gas Analyzer 210GA 210
⚙
Flexible selection of the measuring principle for the gas and process conditionsGas Analyzer 210
✓
High long-term stability and low measurement driftGas Analyzer 210
✓
Reduced calibration effort and lower service requirementsGas Analyzer 210
✓
Automatic zero-point correction in the NDIR configurationGas Analyzer 210
✓
Monitoring of one to eight sampling pointsGas Analyzer 210
✓
Straightforward integration into a higher-level control systemGas Analyzer 210
1–8sample inputs
1 s / 20 smeasurement interval
up to 100 vol.%gas-dependent range
13 kgweight
Instrument overview

The instrument and its role in the measurement system

Gas Analyzer 210 is a flexible platform for continuous gas measurement in industrial installations. Depending on the measuring task, it can use single-beam NDIR, an electrochemical sensor or a zirconium-oxide measuring cell. The analyser can therefore be configured for solvent monitoring as well as oxygen, hydrogen or hydrogen-sulphide measurement.

The platform is designed for process control, environmental protection and plant-safety applications. Typical fields include the chemical and pharmaceutical industries, recycling, waste treatment, energy generation and exhaust-gas analysis.

In the NDIR version, the analyser measures infrared-active gases including perchloroethylene (PCE), trichloroethylene (TCE), dichloromethane, R11, R12, cyclopentane and other hydrocarbons. Oxygen can be measured with an electrochemical or ZrO₂ cell, while electrochemical sensors are also available for components such as H₂S and H₂.

Measuring principle

How does Gas Analyzer 210 work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

Single-beam NDIR

Measurement of infrared-active gases. Automatic ZeroLock zero-point correction and cross-sensitivity compensation reduce drift and calibration effort.

02

Electrochemical sensor

A cost-effective measuring principle for components including O₂, H₂S and H₂, particularly at lower concentrations and under controlled sample conditions.

03

Zirconium oxide ZrO₂

An oxygen-measurement principle suitable for elevated temperature and humidity, providing fast response and a long sensor service life.

Equipment and integration

Key features

✓ 128 × 64 mm colour touch display for operation and presentation of measured values
✓ One sample-gas input as standard, expandable to as many as eight inputs
✓ PTFE or stainless-steel gas path selected according to the sample medium
✓ 19-inch housing for installation in analyser racks and complete measurement systems
✓ RS232 as standard; optional Profibus DP, Ethernet/IP, Modbus TCP and Profinet
✓ Up to eight configurable, galvanically isolated 4–20 mA analogue outputs
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

Better process control

Continuous and stable results help identify deviations earlier and allow process parameters to be corrected more quickly, reducing rejected batches, raw-material consumption and energy losses.

02

Automation-system integration

Open communication interfaces and configurable 4–20 mA outputs simplify connection to the existing control system, data acquisition and alarm logic.

03

Safety and compliance

Measurement of critical components supports limit-value supervision, emissions documentation and the plant response to hazardous concentrations. Alarm functions are configured for the individual project.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ Flexible selection of the measuring principle for the gas and process conditions
✓ High long-term stability and low measurement drift
✓ Reduced calibration effort and lower service requirements
✓ Automatic zero-point correction in the NDIR configuration
✓ Monitoring of one to eight sampling points
✓ Straightforward integration into a higher-level control system
Application areas

Where is Gas Analyzer 210 used?

🧪Chemical and pharmaceutical process control
♻Solvent monitoring: PCE, TCE, dichloromethane and hydrocarbons
✓Recycling, waste treatment and energy generation
🌬Exhaust-gas measurement and environmental protection
🛡Supervision of safety-relevant process parameters
⚙Continuous quality control and process optimisation
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

Sample inputs1 as standard; optionally expandable to 8
Measurement interval1 s in continuous mode or 20 s in quasi-continuous mode
Measuring principlesSingle-beam NDIR; electrochemical sensor; zirconium oxide ZrO₂
Example NDIR componentsPCE, R11, R12, cyclopentane and many other infrared-active gases
Example EC componentsO₂, H₂S and H₂
ZrO₂ componentO₂
Measuring rangesUp to 100 vol.% or 0–10,000 ppm, depending on the component and configuration
AccuracyDependent on the measured component and selected range
Standard sample flow4 l/min
Permissible sample pressure0.7–1.1 bar
Gas pathPTFE or stainless steel
Display128 × 64 mm colour touch display
Digital interfacesRS232; optional Profibus DP, Ethernet/IP, Modbus TCP and Profinet
Analogue outputsOptionally up to 8 × 4–20 mA
Warm-up timeFull compliance with the specification after 30 minutes
Power supply230 VAC / 50 Hz, 0.9 A, 207 VA; 115 VAC / 60 Hz and 230 VAC / 60 Hz versions
Housing and protection rating19-inch rack, 400 mm depth; IP20
Weight13 kg
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Sampling-point configuration

The analyser is a single-component instrument. It has one sample input as standard and can be expanded to eight inputs to measure the same component sequentially at different points in the installation.

02

Start-up and stabilisation

Initial measured values may be available earlier, while full compliance with the declared performance is reached after approximately 30 minutes of warm-up.

03

Calibration and maintenance

Long-term stable sensors and automatic ZeroLock correction in the NDIR version reduce calibration effort. The maintenance schedule is selected for the measured gas, sample conditions and the plant's quality requirements.

04

Control-system communication

RS232 is standard. Options include Profibus DP, Ethernet Modbus TCP, Ethernet/IP and Profinet, as well as up to eight configurable and galvanically isolated 4–20 mA outputs.

05

Additional components

Configurations for gases other than those listed are possible. Each application requires verification of the sample properties, expected range and potential cross-sensitivities.

06

Use of measurement results

Stable measurement helps detect deviations early and reduce rejected production, downtime and unnecessary energy or raw-material consumption. The data can also support emissions supervision and designed alarm functions.

Solution selection

Ask about Gas Analyzer 210

Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.

The enquiry will be sent directly to the MES-EKO team.

MES-EKO Sp. z o.o. · Wrocław · (+48) 71 348 64 02 · meseko@meseko.pl