FRESENIUS · Multi-gas online analyser

Gas Analyzer 220

Developed for quick and easy online measurements of up to six process gases where mutual interferences must be compensated and low detection limits are required.

Gas Analyzer 220GA 220
⚙
0–3 NDIR and 0–3 electrochemical channelsGas Analyzer 220
🌡
Cuvette heated to 50 °CGas Analyzer 220
✓
Sample conditioning for inlet pressure up to 100 barGas Analyzer 220
⌁
RS232 standard; industrial interfaces optionalGas Analyzer 220
✓
Application-specific configurationGas Analyzer 220
✓
Integration with the complete measurement systemGas Analyzer 220
0–3 NDIR channels plus additional sensor channels depending on configurationMeasurement channels
Single-beam, heated to 50 °CNDIR cell
PCE, R11, R12, cyclopentane and other IR-active gasesExample components
Gas- and configuration-dependentRange / accuracy
Instrument overview

The instrument and its role in the measurement system

Developed for quick and easy online measurements of up to six process gases where mutual interferences must be compensated and low detection limits are required.

A stationary multi-channel platform for continuous process and emissions gas monitoring. NDIR channels can be combined with additional sensors and application-specific sample handling.

Measuring principle

How does Gas Analyzer 220 work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

Multi-channel NDIR

Infrared absorption channels measure selected IR-active gases continuously.

02

Additional sensor channels

Electrochemical or zirconium-oxide channels can extend the analyser to non-IR components.

03

Pressure compensation

Sample-pressure effects are corrected to improve result stability.

Equipment and integration

Key features

✓ 0–3 NDIR and 0–3 electrochemical channels
✓ Cuvette heated to 50 °C
✓ Sample conditioning for inlet pressure up to 100 bar
✓ RS232 standard; industrial interfaces optional
✓ Measurement channels: 0–3 NDIR channels plus additional sensor channels depending on configuration
✓ NDIR cell: Single-beam, heated to 50 °C
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

Emissions monitoring

Continuous measurement supports limit supervision and plant documentation.

02

Process control

Early detection of deviations enables faster process correction.

03

Multi-component analysis

Several channels provide a common view of the gas composition.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ 0–3 NDIR and 0–3 electrochemical channels
✓ Cuvette heated to 50 °C
✓ Sample conditioning for inlet pressure up to 100 bar
✓ RS232 standard; industrial interfaces optional
✓ Application-specific configuration
✓ Integration with the complete measurement system
Application areas

Where is Gas Analyzer 220 used?

✓Chemistry
✓recycling
🌬environmental monitoring
✓inspection
🧪pharmaceuticals
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

Measurement channels0–3 NDIR channels plus additional sensor channels depending on configuration
NDIR cellSingle-beam, heated to 50 °C
Example componentsPCE, R11, R12, cyclopentane and other IR-active gases
Range / accuracyGas- and configuration-dependent
Sample flow / pressureApprox. 4 l/min; 0.7–1.1 bar with compensation
Gas pathPTFE or stainless steel depending on medium
Power230 VAC / 50 Hz, 207 VA
Housing / weight19-inch, 400 mm depth, IP20; approx. 13 kg
InterfacesRS232 standard; industrial interfaces and analogue outputs optional
Sample outlet1
Measured gases1–3 NDIR plus 1–3 EC components; up to 6 gases depending on configuration
Measurement intervalDependent on component and configuration
Measuring technologiesSingle-beam NDIR, electrochemical sensors and optional ZrO₂ for O₂
Measuring-cell temperature50 °C
Measuring rangeSelected individually for the component and application
Accuracy / detection limitDependent on component, range and optical configuration
CompensationPressure and cross-sensitivity compensation; up to three IR interferents
Sample conditioningOptional sample filter and pressure reducer for inlet pressure up to 100 bar
Internal filterSintered stainless-steel filter
Ambient conditions5–45 °C; up to approx. 90% RH, non-condensing
Display / operation128 × 64 monochrome display; 2.5-inch resistive touch panel
Digital inputs4 × 24 V AC/DC
Digital outputsReady and fault relays plus four configurable outputs; max. 48 V / 500 mA
Analogue outputsOptionally up to eight galvanically isolated 4–20 mA outputs
Power supply230 VAC / 50 Hz, 0.9 A, 207 VA
ReadinessComponent-dependent; full specification after 30 min
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Range selection

Optical path length and range are selected for each component and expected concentration.

02

Sample conditions

Temperature, humidity, pressure and potential interferences must be defined.

03

Communication

Results can be transferred to a higher-level system through industrial interfaces.