FRESENIUS · Hot-gas formaldehyde analyser

Gas Analyzer 315 Formaldehyde

An online NDIR analyser for formaldehyde and other IR-active components in hot, humid gas streams where conventional gas cooling may cause losses.

Gas Analyzer 315 FormaldehydeGA 315 FORMALDEHYDE
✓
Formaldehyde range 0–160 ppmGas Analyzer 315 Formaldehyde
✓
Detection limit 3 ppmGas Analyzer 315 Formaldehyde
♻
Methane and humidity compensationGas Analyzer 315 Formaldehyde
🌡
Heated sample inletGas Analyzer 315 Formaldehyde
✓
Application-specific configurationGas Analyzer 315 Formaldehyde
✓
Integration with the complete measurement systemGas Analyzer 315 Formaldehyde
Formaldehyde (HCHO); configuration-specific additional IR-active componentsMeasured component
Heated NDIR measurement for hot, humid sample gasPrinciple
0–160 ppm in the supplied brochure configurationFormaldehyde range
3 ppm formaldehydeDetection limit
Instrument overview

The instrument and its role in the measurement system

An online NDIR analyser for formaldehyde and other IR-active components in hot, humid gas streams where conventional gas cooling may cause losses.

A specialised heated NDIR analyser for formaldehyde measurement directly in hot, humid exhaust gas, including gas-engine applications. The heated gas path limits HCHO losses caused by cooling and condensation.

Measuring principle

How does Gas Analyzer 315 Formaldehyde work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

NDIR for formaldehyde

The optical system is optimised for the characteristic absorption of HCHO.

02

Hot-gas measurement

The heated cell and sample path keep formaldehyde in the gas phase.

03

Interference compensation

The configured measurement compensates relevant effects from methane, humidity and sample pressure.

Equipment and integration

Key features

✓ Formaldehyde range 0–160 ppm
✓ Detection limit 3 ppm
✓ Methane and humidity compensation
✓ Heated sample inlet
✓ Measured component: Formaldehyde (HCHO); configuration-specific additional IR-active components
✓ Principle: Heated NDIR measurement for hot, humid sample gas
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

Biogas engines

Measurement supports formaldehyde-emissions assessment from combined heat and power units.

02

Representative sample

Avoiding sample cooling reduces HCHO losses to condensate.

03

Combustion optimisation

Emission trends help assess engine settings and fuel-gas quality.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ Formaldehyde range 0–160 ppm
✓ Detection limit 3 ppm
✓ Methane and humidity compensation
✓ Heated sample inlet
✓ Application-specific configuration
✓ Integration with the complete measurement system
Application areas

Where is Gas Analyzer 315 Formaldehyde used?

♻Biogas
♻landfill-gas engines
⚙combustion processes
🏭emissions monitoring
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

Measured componentFormaldehyde (HCHO); configuration-specific additional IR-active components
PrincipleHeated NDIR measurement for hot, humid sample gas
Formaldehyde range0–160 ppm in the supplied brochure configuration
Detection limit3 ppm formaldehyde
CompensationMethane, humidity and sample-pressure compensation
Pressure0.7–1.1 bar
Power230 V / 50 Hz; 1300 VA
InterfaceRS232 standard; project-specific outputs/interfaces
AccuracyBelow 5% of measured value
Sample inputOne heated gas input on the front panel
Sample temperatureComponents in gas streams up to 300 °C with suitable heated sampling
Sample flowApprox. 4 l/min
Gas pathStainless steel with compression fittings
Internal filter90 µm sintered stainless-steel filter
Sample connectionQuick coupling for heated analytical line
Ambient conditions5–45 °C; up to approx. 90% RH, non-condensing
Display840 × 640 pixel touch panel
Digital inputs6 × 24 V AC/DC
Digital outputsOne ready relay and four relay outputs; max. 48 V / 500 mA
Analogue outputsFour galvanically isolated 4–20 mA outputs
Housing19-inch rack, 400 mm depth, IP20
Warm-up timeApprox. 30 min at 20 °C ambient
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Temperature control

The complete path to the cell must remain above the condensation point.

02

Exhaust-gas matrix

Humidity and potential interfering components must be defined before selection.

03

Gas-path service

Heated lines and filters require periodic inspection for contamination and free flow.

Solution selection

Ask about Gas Analyzer 315 Formaldehyde

Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.

The enquiry will be sent directly to the MES-EKO team.

MES-EKO Sp. z o.o. · Wrocław · (+48) 71 348 64 02 · meseko@meseko.pl