FRESENIUS · High-sensitivity multi-gas NDIR analyser

Gas Analyzer 320

Enables measurement of up to six IR-active gases where very low detection limits and sophisticated cross-sensitivity compensation are required.

Gas Analyzer 320GA 320
✓
NDIR single-beam methodGas Analyzer 320
✓
20-second measurement intervalGas Analyzer 320
▣
7-inch 800 × 480 colour touch displayGas Analyzer 320
✓
Stainless-steel internal gas routingGas Analyzer 320
✓
Application-specific configurationGas Analyzer 320
✓
Integration with the complete measurement systemGas Analyzer 320
1–6 IR-active gases simultaneouslyMeasured components
Single-beam NDIR; cell heated to 50 °CPrinciple
20 sMeasurement interval
Approx. 4 l/min; 0.7–1.1 bar with compensationSample flow / pressure
Instrument overview

The instrument and its role in the measurement system

Enables measurement of up to six IR-active gases where very low detection limits and sophisticated cross-sensitivity compensation are required.

A multi-gas NDIR analyser for simultaneous measurement of as many as six infrared-active components. It is intended for demanding process, greenhouse-gas and refrigerant applications.

Measuring principle

How does Gas Analyzer 320 work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

Multi-gas NDIR

Several optical wavelengths allow simultaneous determination of multiple IR-active components.

02

Heated measuring cell

The cell is maintained at 50 °C to reduce condensation risk and stabilise the gas matrix.

03

Cross-sensitivity correction

The integrated computer corrects configured interactions between measured gases.

Equipment and integration

Key features

✓ NDIR single-beam method
✓ 20-second measurement interval
✓ 7-inch 800 × 480 colour touch display
✓ Stainless-steel internal gas routing
✓ Measured components: 1–6 IR-active gases simultaneously
✓ Principle: Single-beam NDIR; cell heated to 50 °C
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

One common analyser

Simultaneous channels simplify the system compared with several single-gas instruments.

02

Greenhouse-gas monitoring

Documented configurations include CH₄, CO₂ and CO; other IR-active gases require configuration confirmation.

03

Industrial integration

Touch operation and industrial interfaces support complete analyser systems.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ NDIR single-beam method
✓ 20-second measurement interval
✓ 7-inch 800 × 480 colour touch display
✓ Stainless-steel internal gas routing
✓ Application-specific configuration
✓ Integration with the complete measurement system
Application areas

Where is Gas Analyzer 320 used?

✓Chemistry
✓recycling
🌬environment
✓monitoring
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

Measured components1–6 IR-active gases simultaneously
PrincipleSingle-beam NDIR; cell heated to 50 °C
Measurement interval20 s
Sample flow / pressureApprox. 4 l/min; 0.7–1.1 bar with compensation
Gas pathStainless steel
Display7-inch, 800 × 480 colour touch display with integrated PC
Power230 VAC / 50 Hz, 207 VA
Housing / weight19-inch, 400 mm depth, IP20; approx. 16 kg
InterfacesRS232; optional Profibus, Ethernet and Profinet
Sample inputs / outlet1 input standard, expandable to 6; 1 outlet
Measuring-cell temperature50 °C
Measuring rangesSelected individually for the gases and application
Accuracy / detection limitDependent on measured gas, range and configuration
Pressure compensationAutomatic; standard sample-pressure range 0.7–1.1 bar
Sample conditioningOptional filter and pressure reducer for inlet pressure up to 100 bar
Internal filterSintered stainless-steel filter
Sample connections6/4 compression fittings; CK 6/4 optional
Ambient conditions5–45 °C; up to approx. 90% RH, non-condensing
Digital inputs4 × 24 V AC/DC
Digital outputsReady relay and four relay outputs, expandable to eight
Analogue outputsUp to eight galvanically isolated 4–20 mA outputs
Power supply230 VAC / 50 Hz, 0.9 A, 207 VA; 115/230 VAC 60 Hz optional
ReadinessGas-dependent; full specification after 30 min
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Gas configuration

Components, ranges and optical channels are selected together for the target matrix.

02

Sample preparation

The gas must reach the analyser without condensation or particulate contamination.

03

Validation

Calibration and cross-sensitivity correction are verified for the final gas combination.

Solution selection

Ask about Gas Analyzer 320

Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.

The enquiry will be sent directly to the MES-EKO team.