Multi-gas NDIR
Several optical wavelengths allow simultaneous determination of multiple IR-active components.
Enables measurement of up to six IR-active gases where very low detection limits and sophisticated cross-sensitivity compensation are required.
GA 320Enables measurement of up to six IR-active gases where very low detection limits and sophisticated cross-sensitivity compensation are required.
A multi-gas NDIR analyser for simultaneous measurement of as many as six infrared-active components. It is intended for demanding process, greenhouse-gas and refrigerant applications.
The rear-panel view helps assess sample connections, communication interfaces and system integration.


The measuring principle, gas path and sample conditioning are selected for the application.
Several optical wavelengths allow simultaneous determination of multiple IR-active components.
The cell is maintained at 50 °C to reduce condensation risk and stabilise the gas matrix.
The integrated computer corrects configured interactions between measured gases.
Measurement results can support process optimisation, reporting, quality control and designed alarm functions.
Simultaneous channels simplify the system compared with several single-gas instruments.
Documented configurations include CH₄, CO₂ and CO; other IR-active gases require configuration confirmation.
Touch operation and industrial interfaces support complete analyser systems.
The final configuration depends on gases, ranges, sample conditions and system integration.
The range and final configuration are confirmed for the medium and process conditions.
| Measured components | 1–6 IR-active gases simultaneously |
|---|---|
| Principle | Single-beam NDIR; cell heated to 50 °C |
| Measurement interval | 20 s |
| Sample flow / pressure | Approx. 4 l/min; 0.7–1.1 bar with compensation |
| Gas path | Stainless steel |
| Display | 7-inch, 800 × 480 colour touch display with integrated PC |
| Power | 230 VAC / 50 Hz, 207 VA |
| Housing / weight | 19-inch, 400 mm depth, IP20; approx. 16 kg |
| Interfaces | RS232; optional Profibus, Ethernet and Profinet |
| Sample inputs / outlet | 1 input standard, expandable to 6; 1 outlet |
| Measuring-cell temperature | 50 °C |
| Measuring ranges | Selected individually for the gases and application |
| Accuracy / detection limit | Dependent on measured gas, range and configuration |
| Pressure compensation | Automatic; standard sample-pressure range 0.7–1.1 bar |
| Sample conditioning | Optional filter and pressure reducer for inlet pressure up to 100 bar |
| Internal filter | Sintered stainless-steel filter |
| Sample connections | 6/4 compression fittings; CK 6/4 optional |
| Ambient conditions | 5–45 °C; up to approx. 90% RH, non-condensing |
| Digital inputs | 4 × 24 V AC/DC |
| Digital outputs | Ready relay and four relay outputs, expandable to eight |
| Analogue outputs | Up to eight galvanically isolated 4–20 mA outputs |
| Power supply | 230 VAC / 50 Hz, 0.9 A, 207 VA; 115/230 VAC 60 Hz optional |
| Readiness | Gas-dependent; full specification after 30 min |
Key information for design, commissioning and subsequent analyser operation.
Components, ranges and optical channels are selected together for the target matrix.
The gas must reach the analyser without condensation or particulate contamination.
Calibration and cross-sensitivity correction are verified for the final gas combination.
Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.