NDIR channels
Methane and carbon dioxide are measured over wide volume-concentration ranges.
A portable analyser for spot measurements of biogas, digester gas and landfill gas at multiple locations in the field.
GAP 100A portable analyser for spot measurements of biogas, digester gas and landfill gas at multiple locations in the field.
A portable analyser for spot measurements and mobile biogas-plant checks. NDIR measurement of CH₄ and CO₂ is combined with electrochemical O₂ and H₂S sensors.
The measuring principle, gas path and sample conditioning are selected for the application.
Methane and carbon dioxide are measured over wide volume-concentration ranges.
Oxygen and hydrogen sulphide channels complement biogas quality and safety checks.
The internal pump and battery support field operation at successive measurement points.
Measurement results can support process optimisation, reporting, quality control and designed alarm functions.
One instrument can check digesters, gas lines and upgrading stages.
Stored readings support comparison of measurement points and service visits.
The combined gas channels provide a quick view of biogas quality.
The final configuration depends on gases, ranges, sample conditions and system integration.
The range and final configuration are confirmed for the medium and process conditions.
| Current product name | Gas Analyzer Portable 100 (GAP 100) |
|---|---|
| Measured components | CH₄ and CO₂ by NDIR; H₂S and O₂ by electrochemical sensors |
| Ranges | CH₄ 0–100 vol.%; CO₂ 0–65 or 0–100 vol.%; O₂ 0–25 vol.% |
| H₂S ranges | 0–2,000 ppm standard; 0–10,000 ppm option |
| Accuracy | Below 5% of measured value |
| Pump | Approx. 2.5 l/min |
| Battery / runtime | 10.8 V, 8.7 Ah; up to 8 h |
| Memory | Approx. 12,000 readings |
| Housing / weight | 348 × 303 × 125 mm, IP54; 4.2 kg |
| Interface | RS232 |
| Detection limits | CH₄ 0.1 vol.%; CO₂ 0.1 vol.%; H₂S 1 ppm; O₂ 0.1 vol.% |
| Optical technology | Dual-beam NDIR for CH₄ and CO₂ |
| Readiness | Full specification after approx. 5 min |
| Operating time | Up to approx. 8 h per charge |
Key information for design, commissioning and subsequent analyser operation.
Avoid condensate and allow the reading to stabilise before storing a result.
The expected H₂S concentration must be matched to the installed sensor range.
Charge condition and pump flow should be checked before field work.
Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.