FRESENIUS · Compressor sample gas cooler

Gas Cooler RCI 500

A compressor cooler for stable sample-gas dew point and reliable protection of downstream analysers.

Gas Cooler RCI 500RCI 500
✓
Stable gas outlet dew pointGas Cooler RCI 500
▣
Continuous operationGas Cooler RCI 500
💧
Condensate removalGas Cooler RCI 500
✓
System integrationGas Cooler RCI 500
✓
Application-specific configurationGas Cooler RCI 500
✓
Integration with the complete measurement systemGas Cooler RCI 500
Sample-gas cooling and stable outlet dew pointFunction
Compact 19-inch compressor coolerFormat
Duran glassHeat exchanger
Up to 260 l/hMaximum throughput
Instrument overview

The instrument and its role in the measurement system

A compressor cooler for stable sample-gas dew point and reliable protection of downstream analysers.

A compact 19-inch compressor cooler for stable sample-gas dew point and continuous analyser protection.

Measuring principle

How does Gas Cooler RCI 500 work?

The measuring principle, gas path and sample conditioning are selected for the application.

01

Compressor cooling

The heat exchanger cools the sample and separates condensable moisture.

02

Duran-glass exchanger

A removable corrosion-resistant heat exchanger simplifies inspection and cleaning.

Equipment and integration

Key features

✓ Stable gas outlet dew point
✓ Continuous operation
✓ Condensate removal
✓ System integration
✓ Function: Sample-gas cooling and stable outlet dew point
✓ Format: Compact 19-inch compressor cooler
Value for the installation

More than a concentration reading

Measurement results can support process optimisation, reporting, quality control and designed alarm functions.

01

Stable analyser inlet

A controlled outlet dew point improves measurement repeatability.

02

Condensate management

Continuous removal prevents water carry-over into the analyser.

03

Rack integration

The 19-inch format supports complete stationary analysis systems.

In practice

User benefits

The final configuration depends on gases, ranges, sample conditions and system integration.

✓ Stable gas outlet dew point
✓ Continuous operation
✓ Condensate removal
✓ System integration
✓ Application-specific configuration
✓ Integration with the complete measurement system
Application areas

Where is Gas Cooler RCI 500 used?

✓Continuous gas-analysis systems
⚙process monitoring
⚙Continuous process monitoring
✓Industrial quality control
Parameters

Technical data

The range and final configuration are confirmed for the medium and process conditions.

FunctionSample-gas cooling and stable outlet dew point
FormatCompact 19-inch compressor cooler
Heat exchangerDuran glass
Maximum throughputUp to 260 l/h
Residual moistureApprox. 0.86 vol.% under stated reference conditions
ConfigurationConfirm inlet conditions, ambient temperature and condensate removal for the project
Dew point5 °C
Cooling capacityMaximum 90 kJ/h
Condensate removalPeristaltic pump
Ambient conditions5–45 °C
Control / readinessTouch display with temperature and humidity control; approx. 15 min readiness at 20 °C
Weight15.5 kg
InterfacesRS232; optional Profibus DP, Modbus TCP, Ethernet/IP, Profinet and 4–20 mA
Operation and integration

Practical information

Key information for design, commissioning and subsequent analyser operation.

01

Thermal load

Inlet temperature, ambient temperature and sample flow determine the required capacity.

02

Drainage

Condensate removal must be matched to continuous operating conditions.

03

Maintenance

The exchanger and condensate path should remain accessible for service.

Solution selection

Ask about Gas Cooler RCI 500

Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.

The enquiry will be sent directly to the MES-EKO team.

MES-EKO Sp. z o.o. · Wrocław · (+48) 71 348 64 02 · meseko@meseko.pl