Up to three NDIR channels
Infrared absorption channels monitor configured solvent or refrigerant components.
A cost-effective stationary NDIR instrument designed exclusively for monitoring high concentration ranges in solvent-containing gas mixtures.
SMART CONTROL 300A cost-effective stationary NDIR instrument designed exclusively for monitoring high concentration ranges in solvent-containing gas mixtures.
A compact stationary NDIR controller for continuous monitoring of solvent and refrigerant mixtures.
The measuring principle, gas path and sample conditioning are selected for the application.
Infrared absorption channels monitor configured solvent or refrigerant components.
The 50 °C cell improves stability and reduces condensation risk.
Changes in sample pressure are compensated within the operating range.
Measurement results can support process optimisation, reporting, quality control and designed alarm functions.
Continuous concentration trends reveal leaks and process deviations.
Several optical channels can be combined in one housing.
Interfaces support alarm, recording and higher-level control functions.
The final configuration depends on gases, ranges, sample conditions and system integration.
The range and final configuration are confirmed for the medium and process conditions.
| Measured channels | 1–3 NDIR channels |
|---|---|
| Example components | PCE, KWL and refrigerants |
| Cell temperature | 50 °C |
| Accuracy | Below 5% of measured value |
| Measurement interval | 20 s |
| Pressure | 0.7–1.1 bar, compensated |
| Pump | Approx. 4 l/min |
| Power | 230 VAC / 50 Hz, 207 VA |
| Housing / weight | 310 × 133 × 221 mm; 4.7 kg |
| Interfaces | RS232 standard; optional industrial interfaces |
| Sample inputs / outlet | 1 input standard, expandable to 3; 1 outlet |
| Range / resolution | Dependent on measured component |
| Result correction | Pressure and cross-sensitivity compensation |
| Sample connection | CK 6/4; optional compression fitting 6/4 |
| Digital inputs | 4 × 24 V AC/DC |
| Digital outputs | Ready, fault and four relay outputs; expandable to eight |
| Analogue outputs | Optionally up to eight galvanically isolated 4–20 mA outputs |
| Ambient conditions | 5–45 °C; up to approx. 90% RH, non-condensing |
| Dimensions / weight | 310 × 133 × 221 mm; 4.7 kg |
| Power options | 230 VAC / 50 Hz, 207 VA; 115/230 VAC 60 Hz versions |
| Readiness | Component-dependent; full specification after approx. 30 min |
Key information for design, commissioning and subsequent analyser operation.
Optical filters and ranges are configured for the target mixture.
Potential interferences and condensation risk must be assessed.
The selected industrial interfaces are configured during project engineering.
Provide the key measurement information. MES-EKO will check the instrument configuration and required sampling components.