GASERA ONE CF4
A high-sensitivity analyser for continuous monitoring of trace tetrafluoromethane (CF₄). GASERA ONE CF4 combines CEPAS technology and a QCL laser for selective measurements in clean-room, semiconductor, laboratory and process applications.
CF₄ measurement where accuracy and stability matter
The instrument combines CEPAS photoacoustic detection with a QCL laser, making it suitable for continuous monitoring of molecular contamination at very low concentrations.
LoD <0.1 ppb
Selective monitoring of trace CF₄ where rapid detection of even small changes is important.
CEPAS + QCL
Photoacoustic detection combined with a Mid-IR quantum cascade laser operating in a CF₄ absorption band.
Long-term stability
Direct absorption measurement and a background-free design reduce drift during long-term operation.
No wet chemistry
The analyser requires no consumables or wet chemistry, simplifying operation and maintenance.
Typical application areas
The primary application of GASERA ONE CF4 is airborne molecular contamination monitoring in clean rooms, semiconductor production and microelectronics.
Semiconductor industry
CF₄ monitoring in clean rooms and during etching, cleaning and other processes using fluorinated compounds.
Laboratories and R&D
Research setups for trace-level CF₄ measurement, method validation and technology testing.
Emission monitoring
Monitoring molecular contamination in clean-room air and production areas.
Process control
Rapid detection of concentration spikes, alarms and trend analysis in critical processes.
Research institutes
Measurements for scientific institutions, reference laboratories and quality departments in high-tech industry.
Greenhouse gases
Tracking emissions and leaks of fluorinated compounds in industrial and environmental applications.
Trace-gas measurement technology
GASERA ONE CF4 uses infrared photoacoustic spectroscopy, a patented optical MEMS microphone and a QCL source.
Continuous monitoring with minimal servicing
CEPAS provides high sensitivity and stability with a short optical path, enabling continuous operation, rapid detection of concentration spikes and long intervals between calibrations.
Key technical information
The table summarises key information for initial instrument selection. Final performance must be confirmed for the specific configuration and application.
| Parameter | Information |
|---|---|
| Measured gas | Tetrafluoromethane / CF₄ |
| Measurement method | IR photoacoustic spectroscopy, CEPAS, QCL laser |
| Detection limit | Below 0.1 ppb |
| Response time | User configurable, from approximately 10 seconds to several minutes |
| Dynamic range | More than five orders of magnitude |
| Repeatability | <1% of the measured value at the calibration concentration |
| Accuracy | Better than 5% at the calibration concentration; limited by calibration-gas accuracy |
| Housing | 19-inch 3U, benchtop or 19-inch rack mounting |
| Dimensions and weight | 48.4 × 13.9 × 44 cm; approximately 13 kg |
| Power supply | 90–264 VAC, 47–63 Hz; maximum power consumption 75 W |
| Interfaces | Ethernet, USB; optional RS485, RS232, current/voltage signal, MODBUS and AK protocol |
| Operating conditions | 0 to +49 °C, non-condensing humidity, 750–1050 mbar, IP20 |
| Gas sample | 0 to +49 °C, non-condensing humidity, flow approximately 1 l/min, particles <1 µm |
| Local support | Configuration selection, commissioning, training, service and technical support from MES-EKO |
Note: technical data may vary by configuration and current product version. Before preparing an offer, MES-EKO confirms the application requirements and appropriate analyser variant.
Need an analyser for your application?
Contact MES-EKO for an initial technical consultation and help defining the CF₄ measurement requirements.
Send an enquiry(+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl