GASERA ONE FORMALDEHYDE
A formaldehyde analyser for continuous air monitoring, chamber studies, material-emission testing and laboratory applications. It combines photoacoustic technology with a Mid-IR QCL laser.
ONE FORMALDEHYDEWhy is formaldehyde measurement important?
Formaldehyde is a volatile organic compound found in building materials, wood products, paints, combustion processes and indoor air. At low concentrations it requires highly sensitive, selective measurement.
What does GASERA ONE FORMALDEHYDE provide?
A solution designed for selective, automatic formaldehyde monitoring without conventional sample collection, sample preparation or reagents.
Real-time results
Direct measurement makes it possible to observe formaldehyde concentration changes as they occur.
Very high sensitivity
Gasera materials specify a detection limit below 1 ppb, including less than 800 ppt at 60 seconds.
No consumables
The analyser requires no reagents or measurement cartridges.
Selectivity for HCHO
The QCL operates on a fundamental Mid-IR formaldehyde absorption line.
Low impact on the chamber
The low sample volume limits disturbance of equilibrium during chamber studies.
Long-term stability
Recommended recalibration interval according to application materials: 12 months.
DNPH or direct measurement?
The established DNPH method is valuable as a reference method, but routine use requires sample collection, reagents and laboratory analysis. GASERA ONE shortens the path from sample to result.
DNPH method
GASERA ONE
Trace-gas measurement technology
GASERA ONE FORMALDEHYDE uses cantilever-enhanced photoacoustic spectroscopy and a QCL selected for formaldehyde.
HCHO / CH₂O

Validated applications and results
The page includes manufacturer application materials: a DNPH comparison, IRCELYON linearity results and a test-chamber image, providing documented context alongside the product description.
Measurement and data processing can be completed much faster, without sample preparation.
Max. 75 W; Ethernet, USB, MODBUS, AK


Tikkurila / PPG
Formaldehyde-emission tests on paints and coatings in test chambers, highlighting faster measurement without sample preparation and lower sampling volume.
IRCELYON
Testing air-purification methods and measuring formaldehyde at low concentrations in a test chamber.
Air quality
Formaldehyde monitoring in buildings and ambient air, including differences between rooms and the effect of ventilation.
Typical application areas
The analyser is particularly relevant where fast, selective and repeatable low-level formaldehyde measurement is required.
Indoor Air Quality
Formaldehyde measurement in buildings, after refurbishment and in public facilities.
Paints and coatings
Product-emission studies, test chambers and formulation comparisons.
Building materials
Panels, furniture, adhesives, resins and wood-based products.
R&D and laboratories
Method validation, VOC studies and chamber experiments.
Filters and air purification
Assessment of filters, catalysis and photocatalysis.
Ambient air
Monitoring atmospheric background and urban sources.
Industry
Monitoring workplaces, processes and potential emissions.
Multipoint measurement
Automated measurements from multiple locations using a Multipoint Sampler.
Key specifications
The data provide a practical product-page summary. Detailed configurations and ranges must be confirmed for the selected analyser variant.
| Parameter | Information |
|---|---|
| Measured compound | Formaldehyde HCHO / CH₂O |
| Technology | Cantilever-enhanced photoacoustic spectroscopy + Mid-IR QCL laser |
| Detection limit | <1 ppb; Pittcon materials report <800 ppt at 60 s |
| Dynamic range | More than five orders of magnitude according to application materials |
| Recalibration | Recommended interval: 12 months |
| Consumables | No reagents or cartridges |
| Gas flow | Approximately 1 l/min in the GASERA ONE specification |
| Dimensions / weight | 48 × 14 × 45 cm; approximately 13 kg depending on model |
| Applications | IAQ, ambient air, chamber studies, material emissions, R&D and filter testing |
Note: technical values may depend on instrument configuration and application conditions.
Select a formaldehyde analyser for your application
Contact MES-EKO if you require HCHO measurement for indoor air, test chambers, R&D or industrial monitoring.
Contact MES-EKONo consumables