GASERA ONE HCl
A selective photoacoustic analyser for continuous ppb-level hydrogen chloride monitoring in ambient air, fence-line and industrial applications.
ONE HClHCl measurement below 10 ppb
GASERA ONE HCl combines a tunable diode laser with cantilever-enhanced photoacoustic detection for selective and stable hydrogen chloride monitoring in ambient air.
Stable monitoring without wet chemistry
The instrument is designed for continuous field and stationary operation and rapid response to leaks and emission events.
The gas cell is stabilised to 50°C and 200 mbar to minimise drift caused by changes in ambient conditions.
Built-in gas exchange, numerical and graphical display, and user-configurable monitoring tasks.
No consumables or wet chemistry and a long recommended recalibration interval.
Portable construction for fence-line, workplace and periodic monitoring campaigns.
TDLAS combined with CEPAS detection
A tunable diode laser operates at a fundamental HCl absorption line, while the patented cantilever sensor measures the resulting photoacoustic signal.
How does the measurement work?
- The built-in gas exchange system introduces a small sample volume.
- The TDLAS source selectively excites the hydrogen chloride absorption line.
- Absorption produces a periodic pressure wave in the gas cell.
- The MEMS cantilever detects the extremely small photoacoustic signal.
- The result is displayed numerically and graphically and stored.
What must be confirmed?
- expected concentration range and response time,
- sample humidity, temperature, pressure and matrix,
- sample-line material and length for reactive HCl,
- installation location and sampling method,
- data logging and communication requirements.
GASERA ONE HCl specification
Performance published by the manufacturer for the current HCl configuration.
| Parameter | Information |
|---|---|
| Measured gas | Hydrogen chloride (HCl) |
| Detection limit | Below 10 ppb |
| Dynamic range | 0–10 ppm |
| Measurement principle | TDLAS at a fundamental HCl absorption line combined with cantilever-enhanced photoacoustic detection |
| Gas cell | Stabilised to 50°C and 200 mbar |
| Sample volume | Few ml |
| Operation | Continuous standalone monitoring with built-in gas exchange |
| Recalibration | Recommended interval of 12 months |
| Monitoring tasks | User configurable |
| User interface | Intuitive control; built-in display presents results numerically and graphically |
| Consumables | No consumables or wet chemistry |
| Installation | Field and stationary operation; sample handling selected for the application |
Protecting people, the environment and assets
Continuous low-level measurement supports rapid response to HCl releases and helps reduce health and corrosion risks.