GASERA · Multipoint sampling · 12- or 24-channel configurations

GASERA MULTIPOINT SAMPLER

An expansion module for GASERA ONE analysers, providing automatic sequential sampling from multiple lines or sampling bags.

GASERA MULTIPOINT SAMPLER — product view 2MULTIPOINT SAMPLER
Programmable sampling sequence
Animal husbandry. Final performance depends on the selected gases, sample matrix and operating conditions.
Measurement-system expansion

One analyser. Multiple measurement locations.

MULTIPOINT SAMPLER increases the number of analyser sample inlets and enables programmed switching between points without manually reconnecting tubing.

01

Up to 24 points

Configurations with 12 or 24 sample inlets are available.

02

Automatic sequence

The system samples selected lines in sequence according to a programmed schedule.

03

Adjustable sampling time

The order and sampling time can be set for each point.

04

Control from the analyser

Configuration is performed through the GASERA ONE graphical interface.

Workflow

Automated multipoint monitoring

The module can switch between process lines, rooms, chambers, fence-line points or sampling bags.

1

Connect the lines

Sampling lines from individual locations are connected to the module inlets.

2

Program the sequence

Points and measurement order are selected in the GASERA ONE interface.

3

Set the sampling time

The sampling duration and time assigned to each point are defined.

4

Monitor automatically

The system switches channels and transfers the sample to the analyser without operator intervention.

Example applications

From buildings to facility boundaries

The solution is particularly useful where the same set of gases must be monitored at several locations.

🐄

Animal husbandry

Comparison of concentrations in multiple building zones or at different positions.

🏭

Fence-line monitoring

Sequential measurements along a facility boundary and at selected emission points.

🏢

Air quality and occupational safety

Monitoring multiple rooms, workplaces or process areas.

🏥

Anaesthetic gases

Monitoring waste anaesthetic gases in several rooms or installation points.

☀️

Photocatalysis studies

Automatic sampling from several reactors or experimental chambers.

🌱

Soil analysis

Support for multiple chambers or positions used in soil-emission studies.

🧪

Clean rooms

Detecting differences between clean zones and process lines.

🎒

Sampling bags

Automated analysis of a series of previously collected samples.

Range defined by the analyser

Handling multiple gas groups

MULTIPOINT SAMPLER does not measure gases independently. It transfers samples to a connected GASERA ONE analyser, and the measured compounds depend on that analyser configuration.

Anaesthetic gases

Desflurane, enflurane, isoflurane, sevoflurane and others.

CFCs and PFCs

CF₄, C₂F₆, R-13, R-134a and other fluorinated compounds.

Corrosive gases

HCl, HCN and HF at low concentration levels.

Hydrocarbons

CH₄, C₂H₂, C₂H₄, C₂H₆ and others.

Inorganic gases

CO, CO₂, H₂O, H₂S, NO, NO₂, N₂O, NF₃, NH₃, SF₆ and SO₂.

VOCs

Acetone, benzene, ethanol, formaldehyde, methanol, toluene, xylenes and others.

Integration

Part of the GASERA ONE system

The module is available in a 19-inch rack enclosure with rear-panel connections. Operation remains integrated in the analyser user interface.

GASERA MULTIPOINT SAMPLER — product view 3
Clean roomsCompatible with GASERA ONE configurations
Automatic multipoint samplingFunction
Automatic multipoint samplingInlets
12- and 24-inlet versionsControl
Basic data

Key technical information

The manufacturer page does not provide a complete table of dimensions, weight or gas-path materials. These must be confirmed for the offered configuration.

ParameterInformation
PurposeAutomatic multipoint sampling for GASERA ONE analysers
Number of inlets12- and 24-sample-inlet versions available
ControlFrom the GASERA ONE graphical user interface
ProgrammingPoint order and sampling time for individual lines or bags
Construction19-inch rack housing with rear-panel connections
CompatibilityGASERA ONE analysers; configuration must be selected for the model and application
MaintenanceDescribed by the manufacturer as maintenance-free
Measured-gas rangeDepends on the connected GASERA ONE analyser

How many points should one analyser cover?

Send us the number of locations, line lengths, measured gases, required measurement cycle and analyser model. We will select a 12- or 24-channel version and define system operation.

Contact MES-EKO
MES-EKO Sp. z o.o.
Fence-line monitoring. Final performance depends on the selected gases, sample matrix and operating conditions.
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl