Up to 24 points
Configurations with 12 or 24 sample inlets are available.
An expansion module for GASERA ONE analysers, providing automatic sequential sampling from multiple lines or sampling bags.
MULTIPOINT SAMPLERMULTIPOINT SAMPLER increases the number of analyser sample inlets and enables programmed switching between points without manually reconnecting tubing.
Configurations with 12 or 24 sample inlets are available.
The system samples selected lines in sequence according to a programmed schedule.
The order and sampling time can be set for each point.
Configuration is performed through the GASERA ONE graphical interface.
The module can switch between process lines, rooms, chambers, fence-line points or sampling bags.
Sampling lines from individual locations are connected to the module inlets.
Points and measurement order are selected in the GASERA ONE interface.
The sampling duration and time assigned to each point are defined.
The system switches channels and transfers the sample to the analyser without operator intervention.
The solution is particularly useful where the same set of gases must be monitored at several locations.
Comparison of concentrations in multiple building zones or at different positions.
Sequential measurements along a facility boundary and at selected emission points.
Monitoring multiple rooms, workplaces or process areas.
Monitoring waste anaesthetic gases in several rooms or installation points.
Automatic sampling from several reactors or experimental chambers.
Support for multiple chambers or positions used in soil-emission studies.
Detecting differences between clean zones and process lines.
Automated analysis of a series of previously collected samples.
MULTIPOINT SAMPLER does not measure gases independently. It transfers samples to a connected GASERA ONE analyser, and the measured compounds depend on that analyser configuration.
Desflurane, enflurane, isoflurane, sevoflurane and others.
CF₄, C₂F₆, R-13, R-134a and other fluorinated compounds.
HCl, HCN and HF at low concentration levels.
CH₄, C₂H₂, C₂H₄, C₂H₆ and others.
CO, CO₂, H₂O, H₂S, NO, NO₂, N₂O, NF₃, NH₃, SF₆ and SO₂.
Acetone, benzene, ethanol, formaldehyde, methanol, toluene, xylenes and others.
The module is available in a 19-inch rack enclosure with rear-panel connections. Operation remains integrated in the analyser user interface.

The manufacturer page does not provide a complete table of dimensions, weight or gas-path materials. These must be confirmed for the offered configuration.
| Parameter | Information |
|---|---|
| Purpose | Automatic multipoint sampling for GASERA ONE analysers |
| Number of inlets | 12- and 24-sample-inlet versions available |
| Control | From the GASERA ONE graphical user interface |
| Programming | Point order and sampling time for individual lines or bags |
| Construction | 19-inch rack housing with rear-panel connections |
| Compatibility | GASERA ONE analysers; configuration must be selected for the model and application |
| Maintenance | Described by the manufacturer as maintenance-free |
| Measured-gas range | Depends on the connected GASERA ONE analyser |
Send us the number of locations, line lengths, measured gases, required measurement cycle and analyser model. We will select a 12- or 24-channel version and define system operation.