GASERA · OEM module · Compact embedded design

GASERA OEM MODULE

A compact OEM module for integration into custom analysers, research setups and measurement systems developed by an integrator. It is not a standalone end-user analyser and requires installation and integration into the target instrument.

GASERA OEM MODULE — product view 2OEM MODULE
Integrated gas exchange
A compact cantilever-enhanced photoacoustic platform intended for mechanical, pneumatic and software integration into customer-developed instruments.
Product concept

A measurement core for your own analyser

OEM MODULE makes it possible to use Gasera technology in a custom design without building the measurement system, gas path and control electronics from scratch.

01

Compact embedded design

The module can be installed in a custom enclosure, control cabinet or mobile measurement system.

02

Custom user interface

The integrator can develop an operator panel, display, application or communications tailored to the final instrument.

03

Flexible sample path

Two sample inlets, one outlet and a PURGE connection support reference-gas and switched-flow arrangements.

04

OEM product development

The platform can form the basis of laboratory or industrial instrumentation, or a dedicated solution for a specific application.

Hardware integration

Key areas of an OEM project

A finished instrument requires correct integration of the module with the enclosure, power supply, gas lines, software and other system components.

GASERA OEM MODULE — product view 3
Compact embedded designAnimal husbandry
Integrated gas exchangeClean-room systems
USB and 12 V DC connectionsEmbedded research instruments
Application-specific light-source configurationApplication-specific
Application validationPhotoacoustic OEM platform
Implementation process

From measurement requirement to finished instrument

An OEM project should start by defining the application before the enclosure and final-product electronics are designed.

1

Define the measurement

Gases, ranges, matrix, response time, sample conditions and continuous-operation requirements.

2

Select the configuration

Module parameters and the required test scope are agreed together with the manufacturer.

3

Build the prototype

The module is integrated with sample conditioning, electronics, software and the enclosure.

4

Validate the system

Validation covers response, stability, interferences, safety and performance under target conditions.

Example directions

A platform for specialised products

The module offers greatest value when a custom form factor, non-standard interface or integration into an existing machine is required.

🏭

Process analysers

Dedicated instruments for process lines and industrial installations.

🧪

Laboratory instrumentation

Systems developed for a specific gas, mixture or experiment.

🧰

Machine integration

Embedding gas measurement into a larger machine or automated test rig.

🚚

Mobile systems

Compact field and measurement systems developed by an integrator.

🛡️

Safety monitoring

Specialised instruments for hazardous substances and leak monitoring.

🌱

Environmental research

Automated field stations and multipoint systems.

🔬

R&D prototypes

Validation of new applications before launching a serial product.

🏷️

Private label

Instruments offered under the integrator brand after the cooperation model is agreed.

Visible connections

Module connections

The following information is based directly on markings visible in the supplied instrument image. The full interface specification must be confirmed for the version offered by the manufacturer.

SAMPLE 1 IN

First sample inlet.

SAMPLE 2 IN

Second sample inlet.

SAMPLE OUT

Gas outlet from the module.

PURGE

Purge-gas connection.

USB / 12 V DC

Instrument communication and power supply.

Scope of confirmed information

Information available at this stage

The public manufacturer page does not provide a complete specification or parameter table. Values that cannot be confirmed have therefore not been added.

ParameterInformation
Product typeOEM measurement module for integration into a final instrument
Sample inletsTwo labelled inlets: SAMPLE 1 IN and SAMPLE 2 IN
Sample outletLabelled SAMPLE OUT connection
PurgeSeparate PURGE connection
CommunicationUSB connector visible on the panel
Power supply12 V DC according to the panel marking
OperationRequires an external interface or software developed as part of the integration
Measurement performanceDepends on the OEM configuration and must be confirmed for the specific application
Compensation Embedded CEPAS engine combining the optical cantilever microphone, photoacoustic cell, gas exchange and signal processing.

Building your own analyser or measurement system?

Send us the application description, measured gases, concentration ranges, sample conditions, expected instrument format and planned project scale. This will provide the basis for a technical consultation with Gasera.

Contact MES-EKO
MES-EKO Sp. z o.o.
GASERA OEM MODULE is configured for Application-specific.
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl
GASERA OEM MODULE — product view 4