GASERA · Research platform · laser spectroscopy

GASERA PA201

A research-grade CEPAS photoacoustic detector for building custom high-sensitivity gas-analysis systems with DFB, QCL, EC-QCL, OPO and other tunable sources.

GASERA PA201 — product view 2PA201
Typical low-ppb detection capability
An open photoacoustic detector platform for use with modulated laser sources. Its optical cantilever microphone provides high sensitivity in a compact sample cell.
PA
CEPAScantilever-enhanced photoacoustic detection
30
Low internal volumeapproximately 30 ml
0.3
Pressure controlselectable 300–1000 mbar
50
Temperature controlcell stabilised up to 50 °C
5×
Multiple source typesDFB, QCL, EC‑QCL, OPO
R&D
Open platformfor research and analyser development
Product concept

A detector for researchers, not a closed analyser

The user selects the light source, spectral range, modulation method and analytical model. PA201 provides an ultra-sensitive photoacoustic cell, optical microphone, gas-exchange control and digital signal readout.

01

Optical cantilever microphone

A silicon MEMS element responds to extremely small pressure changes generated by radiation absorption.

02

Interferometric readout

The movement of the cantilever tip is measured without contact by a laser interferometer with resolution below 10⁻¹² m.

03

Cell for laser sources

A short, low-volume cell provides rapid sample transport, a wide dynamic range and high selectivity.

04

Configuration freedom

The platform supports research on individual gases, mixtures, spectral scanning and identification of unknown components.

Operating principle

From light absorption to an electrical signal

Photoacoustic spectroscopy measures the absorption effect in the sample directly. It does not require determining a small difference between large incident and transmitted signals.

LASERmodulatedCustom analyser developmentGas and light-source dependentMEMScantilever
1
Open photoacoustic detector platformCompatible sources
2
NIR DFB, QCL, EC-QCL, OPO and other modulated sourcesDetection limits
3
Typically ppb with NIR lasers and ppt with MIR QCLsMeasurement pressure
4
Selectable 300–1000 mbarAn optical interferometer measures microscopic cantilever deflection.
Platform architecture

Measurement cell, gas control and DSP readout

The system consists of a measurement module, temperature and gas-exchange controller, and an optical-microphone DSP module. An external laser source and computer are required.

GASERA PA201 gas connections
SAMPLE INsample inlet to the photoacoustic cell
SAMPLE OUTsample outlet after gas exchange
PURGEpurging of the optical section
Optical windowsselected for the light-source wavelength
Pressure controloperation from approximately 0.3 to 1.1 bar abs.
Temperature controlcell stabilisation and drift reduction
Compatibility

A platform for different light sources

PA201 can be adapted to a wide range of sources, from compact diode lasers to broadly tunable Mid-IR sources.

DFBselective measurement of individual absorption lines
QCLhigh power in fundamental mid-infrared absorption bands
EC‑QCLbroad spectral scanning and multi-component analysis
OPObroad tunability for hydrocarbon and VOC research
Supercontinuumbroadband studies and development of new configurations
Research fields

One cell – many research directions

PA201 is particularly valuable when no standard analyser exists or a custom measurement method must be developed.

🔬

Fundamental research

Development of laser spectroscopy, source characterisation and new modulation methods.

⚡

SF₆ and NF₃

Leak detection for gases used in power engineering and the semiconductor industry.

🌫️

CH₄ and VOCs

Fast trace measurements and spectral scanning using OPO or EC-QCL sources.

🏭

Clean rooms

Identification of unknown contaminants and diagnosis of production problems.

🌍

NO₂ and ambient air

Ultra-sensitive measurements with visible lasers for environmental research.

🧪

Chemometrics

Multi-component analysis, spectral-library fitting and mixture identification.

🛡️

Hazardous substances

Development of sensors for chemical precursors and other compounds requiring high selectivity.

🧩

OEM prototyping

Proof-of-concept validation before miniaturisation and deployment of a dedicated analyser.

Publications and results

Validated performance in different configurations

Results depend on the source, optical power, wavelength, integration time and system preparation. The following values illustrate the platform potential, not a universal specification for every configuration.

0,5 ppb

SF₆ in 15 seconds

PA201 combined with a broadly tunable EC-QCL demonstrated highly sensitive SF₆ detection in the presence of NF₃, CH₄ and H₂O.

QCL‑PAS measurement of SF₆ and NF₃
3–4 ppb

CH₄ in approximately 1 second

A compact Mid-IR OPO and PA201 enabled fast, selective methane measurement with an observation time below one second.

OPO laser + PA201 application study
50 ppt

NO₂ in 1 second

In a study published in Optics Letters, the CEPAS platform achieved parts-per-trillion NO₂ detection.

Optics Letters, Vol. 40, No. 13
Technical data

Key PA201 specifications

Final system performance depends on the selected light source, optical windows, sample type and electronics configuration.

ParameterInformation
PurposeResearch photoacoustic cell for laser-based trace-gas measurements
Detection technologyCEPAS photoacoustic sensor with a silicon MEMS cantilever and interferometric readout
Cell volumeBelow 10 ml; cell approximately 95 mm long and 4 mm in diameter
Sample pressure rangeApproximately 0.3–1.1 bar absolute
Operating temperatureTypically 10–45 °C; the cell can be stabilised to approximately 50 °C
Module weightsPA201 module approximately 3.1 kg; DSP approximately 0.7 kg; controller approximately 0.4 kg
Detector module dimensionsApproximately 380 × 198 × 105 mm
Compatible sourcesDFB, QCL, EC-QCL, OPO, visible lasers and other modulated sources
Required external equipmentLaser, computer, gas lines and optical-path components
Output / communicationDSP module and USB software for signal readout and recording
Source materials

Documentation and research examples

This description is based on manufacturer materials, the manual, and selected publications and application notes. Documentation is available from MES-EKO on request.

Planning your own laser-based gas analysis system?

Send us the target component, expected concentration range, gas matrix, available light source and required response time. We will prepare initial assumptions for a PA201 configuration.

Contact MES-EKO
MES-EKO Sp. z o.o.
Open laser-photoacoustic gas-cell and detector platform with an interferometrically read MEMS cantilever and configurable gas exchange.
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl
GASERA PA201 — product view 5