Optical cantilever microphone
A silicon MEMS element responds to extremely small pressure changes generated by radiation absorption.
A research-grade CEPAS photoacoustic detector for building custom high-sensitivity gas-analysis systems with DFB, QCL, EC-QCL, OPO and other tunable sources.
PA201The user selects the light source, spectral range, modulation method and analytical model. PA201 provides an ultra-sensitive photoacoustic cell, optical microphone, gas-exchange control and digital signal readout.
A silicon MEMS element responds to extremely small pressure changes generated by radiation absorption.
The movement of the cantilever tip is measured without contact by a laser interferometer with resolution below 10⁻¹² m.
A short, low-volume cell provides rapid sample transport, a wide dynamic range and high selectivity.
The platform supports research on individual gases, mixtures, spectral scanning and identification of unknown components.
Photoacoustic spectroscopy measures the absorption effect in the sample directly. It does not require determining a small difference between large incident and transmitted signals.
The system consists of a measurement module, temperature and gas-exchange controller, and an optical-microphone DSP module. An external laser source and computer are required.

PA201 can be adapted to a wide range of sources, from compact diode lasers to broadly tunable Mid-IR sources.
PA201 is particularly valuable when no standard analyser exists or a custom measurement method must be developed.
Development of laser spectroscopy, source characterisation and new modulation methods.
Leak detection for gases used in power engineering and the semiconductor industry.
Fast trace measurements and spectral scanning using OPO or EC-QCL sources.
Identification of unknown contaminants and diagnosis of production problems.
Ultra-sensitive measurements with visible lasers for environmental research.
Multi-component analysis, spectral-library fitting and mixture identification.
Development of sensors for chemical precursors and other compounds requiring high selectivity.
Proof-of-concept validation before miniaturisation and deployment of a dedicated analyser.
Results depend on the source, optical power, wavelength, integration time and system preparation. The following values illustrate the platform potential, not a universal specification for every configuration.
PA201 combined with a broadly tunable EC-QCL demonstrated highly sensitive SF₆ detection in the presence of NF₃, CH₄ and H₂O.
QCL‑PAS measurement of SF₆ and NF₃A compact Mid-IR OPO and PA201 enabled fast, selective methane measurement with an observation time below one second.
OPO laser + PA201 application studyIn a study published in Optics Letters, the CEPAS platform achieved parts-per-trillion NO₂ detection.
Optics Letters, Vol. 40, No. 13Final system performance depends on the selected light source, optical windows, sample type and electronics configuration.
| Parameter | Information |
|---|---|
| Purpose | Research photoacoustic cell for laser-based trace-gas measurements |
| Detection technology | CEPAS photoacoustic sensor with a silicon MEMS cantilever and interferometric readout |
| Cell volume | Below 10 ml; cell approximately 95 mm long and 4 mm in diameter |
| Sample pressure range | Approximately 0.3–1.1 bar absolute |
| Operating temperature | Typically 10–45 °C; the cell can be stabilised to approximately 50 °C |
| Module weights | PA201 module approximately 3.1 kg; DSP approximately 0.7 kg; controller approximately 0.4 kg |
| Detector module dimensions | Approximately 380 × 198 × 105 mm |
| Compatible sources | DFB, QCL, EC-QCL, OPO, visible lasers and other modulated sources |
| Required external equipment | Laser, computer, gas lines and optical-path components |
| Output / communication | DSP module and USB software for signal readout and recording |
This description is based on manufacturer materials, the manual, and selected publications and application notes. Documentation is available from MES-EKO on request.
Send us the target component, expected concentration range, gas matrix, available light source and required response time. We will prepare initial assumptions for a PA201 configuration.
Contact MES-EKO