GASERA · FTIR accessory · solid and liquid samples

GASERA PA301

An ultra-sensitive photoacoustic FTIR accessory for direct analysis of solid, semi-solid and liquid samples, often without sample preparation.

GASERA PA301 — product view 2PA301

PA301 is not a standalone analyser. It operates as a photoacoustic detector installed in the sample compartment of an FTIR spectrometer.

When ATR and DRIFTS become inconvenient

PA301 does not require perfect optical contact with the sample, making it suitable for hard, rough, black, strongly absorbing and irregular materials.

01

No ATR pressure

No need to achieve perfect contact with an ATR crystal.

02

No KBr dilution

Powders and minerals can be measured without typical DRIFTS preparation.

03

Black samples

High absorption increases the signal instead of saturating a transmission measurement.

04

Layer analysis

Depth profiling can be performed without destroying the sample.

From sample to spectrum in six steps

Operation resembles a standard FTIR accessory, but the recorded signal is photoacoustic.

1Install PA301in the FTIR sample compartment
2Measure the referenceusing the black reference material
3Place the samplein the sample cup
4Seal the chamberand select the chamber gas
5Move the sledgeto the measurement position
6Record the spectrumin the FTIR software

The sample becomes part of the detector

Absorbed radiation heats the material. Heat passes to the gas in the cell, and periodic pressure changes are measured by an optical cantilever microphone.

FTIR RADIATIONSolids, powders, fibres, pastes, semi-solids and liquidsPreparationMEMSOften none
1. Radiation absorptionSpectral range
UV to far-IR; window and FTIR dependentAbsorbed energy is converted into periodic heating.
Repeatability5% under operating conditions
FTIR scan speedThe optical interferometer reads microscopic deflections.

Higher sensitivity shortens measurement time

Manufacturer materials show an SNR approximately ten times higher than conventional PAS detectors using a condenser microphone.

10×

Higher SNR

A single PA301 scan can provide a result comparable with multiple scans using conventional PAS.

100×

Shorter accumulation

A tenfold SNR increase can reduce the time needed for a comparable result by approximately one hundred times.

AIR

Operation without helium may be possible

In many applications, the high sensitivity allows air to be used instead of helium.

Material depth profiling

Changing mirror velocity, modulation frequency and spectral phase provides information from different depths and separates layer signals.

Surface layer
Coating
Intermediate layer
Base material
Below 1 µm to hundreds of µmThe accessible depth depends on measurement settings and sample thermal properties.
Layer-boundary identificationInterfaces and coating positions can be detected.
Layer-spectrum separationPhase analysis helps distinguish signals from individual materials.
Non-destructive measurementNo mechanical removal of successive layers is required.

FTIR integration and sampling kit

The kit includes sample cups, a black reference and service accessories. Solutions for individual fibres and microscopic particles are also available.

From minerals to individual fibres

A major advantage of PA301 is the wide range of samples that can be measured without complex preparation.

⚫

Black samples

Bitumen, asphalt, carbon black, resins, heavy oils and carbon materials.

🪨

Soils and minerals

Hard, rough and crystalline samples without ATR contact.

💊

Pharmaceuticals

Coatings, tablets and layered materials.

🧵

Fibres and microsamples

Individual fibres, hair and small particles.

🧴

Liquids and semi-solids

Oils, cosmetics, food, paints and viscous materials.

🎨

Art and conservation

Pigments and paint layers in non-destructive measurements.

🧪

Polymers and coatings

Films, adhesives and multilayer materials.

🧬

Biomaterials

Tissues, hair and biological samples with minimal preparation.

Key specifications

Final compatibility depends on the FTIR model and its sample compartment.

ParameterInformation
PurposePhotoacoustic FTIR accessory for solid, semi-solid and liquid samples
DetectionMEMS cantilever with interferometric optical readout
MeasurementDirect photoacoustic absorption
Maximum sample sizeApproximately 10 mm high and 9 mm in diameter
Cell gasAir, nitrogen or helium
Spectral rangeFrom UV to far infrared, depending on the FTIR source and optics
Depth profilingYes, by changing mirror velocity, modulation and phase
SamplesPowders, solids, liquids, pastes, black samples and layered materials
IntegrationCan be adapted to many FTIR systems after mechanical and optical verification

Documentation and application notes

This description is based on manufacturer materials covering black samples, minerals, depth profiling and microsamples. Documentation is available from MES-EKO on request.

Is PA301 compatible with your FTIR?

Send us the FTIR manufacturer and model, sample type, required spectral range and analytical objective. We will check integration feasibility.

Contact MES-EKO
MES-EKO Sp. z o.o.
Photoacoustic FTIR accessory converting absorbed broadband radiation into a pressure signal detected by the optical cantilever microphone.
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl
GASERA PA301 — product view 6