GASERA · flagship product

GASERA ONE PULSE

A configurable multi-gas trace-gas analyser combining cantilever-enhanced photoacoustic detection with selectable infrared light sources. The configuration is selected for the target gases, measurement ranges and interferences, enabling selective, simultaneous trace-gas measurements in laboratories, industry and environmental monitoring.

ONE PULSEGASERA ONE PULSE
Example applications

One platform. Many measurement scenarios.

GASERA ONE PULSE can be configured for specific gases, interferences and sample conditions. The applications below are presented in the manufacturer materials.

🌱

Greenhouse-gas research

Measurements of CH₄, CO₂, N₂O and fluorinated gases in air, soil and water.

🐄

Agriculture and livestock

Emissions from animals, livestock buildings, soil and fertilisation.

⚡

SF₆ and the power industry

Leak detection in switchgear, equipment manufacturing and service.

🏥

Anaesthetic gases

Monitoring of fluranes and N₂O in operating rooms and medical installations.

❄️

Refrigerants

Leak detection of R134a, HFO-1234yf and other HVAC/R refrigerants.

🌬️

Tracer gases

Air-exchange, tightness and flow studies using SF₆ or other tracer gases.

🧪

Photocatalysis and R&D

Evaluation of reactors, materials and research processes.

🧯

Fume-hood testing

Leak measurements and performance testing of laboratory extraction systems using SF₆.

🏭

Occupational safety and industrial emissions

Monitoring of toxic gases, leaks and process emissions.

🛡️

Protection of critical facilities

Continuous monitoring of chemical hazards in infrastructure and high-risk facilities.

▦

Multipoint monitoring

The optional MULTIPOINT SAMPLER enables automatic sampling from up to 12 points.

🔬

Laboratories and pilot installations

Flexible configuration for development, validation and comparative measurements.

CEPAS technology

Why can PULSE measure multiple gases?

GASERA ONE PULSE combines a broadband infrared source, narrow-band optical filters and a patented optically read cantilever sensor. This allows one platform to be configured for many different gases.

1
Gas samplethe internal gas-exchange system delivers the sample to the cell
↓
2
IR source + filtersselected optical bands correspond to target gases and interfering components
↓
3
Photoacoustic cellabsorption of radiation produces local heating and a pressure wave
↓
4
MEMS cantileverthe interferometrically read sensor detects very small pressure changes
↓
5
Multi-component analysisalgorithms convert filter responses into gas concentrations

Key advantages

This is not conventional NDIR. PULSE uses chemometric fitting of sample responses to calibration data, improving selectivity in multi-component mixtures.

✓multi-channel signal analysis and application-specific configuration
✓no reagents, carrier gas or daily sample preparation
✓high sensitivity through cantilever-enhanced PAS
✓stable operation and low operating cost
✓integrated computer, display and gas-exchange system
Portable or stationary

The same instrument in two operating modes

GASERA ONE PULSE normally operates as a benchtop analyser or in a 19-inch rack. For field measurements it can be installed in a dedicated impact-resistant rack case.

Stationary operation

Laboratory, installation or 24/7 monitoring

The self-contained unit with integrated pump, computer and display can operate on a laboratory bench or in a standard 19-inch instrument rack.

✓continuous automatic monitoring
✓integration via Ethernet / AK protocol
✓optional MULTIPOINT SAMPLER for up to 12 points
GASERA ONE PULSE in stationary configuration
Portable operation

Safe transport for field measurements

The optional 19-inch 3U transport enclosure made from impact-resistant plastic protects the analyser during transport and operation outside the laboratory.

✓total weight including analyser: approximately 18 kg
✓compact protected format for mobile applications
✓an external power supply is required in the field
The portable 19-inch 3U enclosure is made from impact-resistant plastic. Including the analyser, the system weighs approximately 18 kg; an external power supply is required during field operation.
Example components

Which gases can PULSE measure?

The list shows example components available in GASERA ONE PULSE configurations. The final set of gases and filters is selected for the application, ranges and possible interferences.

Detection limits declared in the manufacturer table; LoD values are given in ppm. 0.005 ppm corresponds to 5 ppb.

1,1,1,2-tetrafluoroethaneR134a, C₂H₂F₄
LoD 0.01 ppm
HFO1234yfC₃H₂F₄
LoD 0.01 ppm
2-propanolIPA, C₃H₈O
LoD 0.1 ppm
AcetaldehydeC₂H₄O
LoD 0.04 ppm
Acetic acidCH₃COOH
LoD 0.03 ppm
AcetoneC₃H₆O
LoD 0.04 ppm
AcetyleneC₂H₂
LoD 0.05 ppm
AmmoniaNH₃
LoD 0.15 ppm
Carbon dioxideCO₂
LoD 0.4 ppm
Carbon monoxideCO
LoD 0.1 ppm
CyclohexaneC₆H₁₂
LoD 0.01 ppm
DesfluraneC₃H₂F₆O
LoD 0.005 ppm
DichloromethaneDCM, CH₂Cl₂
LoD 0.08 ppm
EnfluraneC₃H₂ClF₅O
LoD 0.005 ppm
EthaneC₂H₆
LoD 0.06 ppm
EthanolEtOH, C₂H₆O
LoD 0.05 ppm
EthyleneC₂H₄
LoD 0.15 ppm
FormaldehydeHCHO / CH₂O
LoD 0.03 ppm
IsofluraneC₃H₂ClF₅O
LoD 0.005 ppm
MethaneCH₄
LoD 0.12 ppm
MethanolMeOH, CH₄O
LoD 0.1 ppm
Nitrogen trifluorideNF₃
LoD 0.02 ppm
Nitrous oxideN₂O
LoD 0.025 ppm
Novec 4710(CF₃)₂CFCN
LoD 0.015 ppm
OctafluorocyclobutaneC₄F₈
LoD 0.008 ppm
SevofluraneC₄H₃F₇O
LoD 0.006 ppm
Sulfur dioxideSO₂
LoD 0.05 ppm
Sulfur hexafluorideSF₆
LoD 0.005 ppm
TetrafluoromethaneCF₄
LoD 0.005 ppm
TrifluoromethaneCHF₃
LoD 0.007 ppm
TolueneC₇H₈
LoD 0.05 ppm
TVOC (EtOH)TVOC
LoD 0.02 ppm
TVOC (Toluene)TVOC
LoD 0.015 ppm
Product positioning

PULSE versus GC and FTIR

Manufacturer materials position PULSE as faster and simpler to operate than GC and as more stable and sensitive in many applications than conventional FTIR.

Conventional approaches

–GC often requires carrier gas, sample preparation and consumables.
–FTIR may require more frequent background procedures and greater operator involvement.
–Multi-component trace measurement can be costly and complex to maintain.

GASERA ONE PULSE

✓Simultaneous measurement of multiple gases in one analyser.
✓No reagents, cartridges or carrier gas.
✓Self-contained unit with pump, display and measurement tasks.
✓Capability for 24/7 operation and integration with supervisory systems.
Operating parameters

Key technical information

Summary of product data. Detailed values and measured components depend on the selected GASERA ONE PULSE configuration.

ParameterInformation
Instrument typeConfigurable GASERA ONE PULSE multi-gas analyser
Measuring principlePhotoacoustic Spectroscopy / Cantilever-Enhanced PAS
Light sourceBroadband IR source with narrow-band optical filters
Gas configurationIndividually selected for target gases, ranges and sample interferences
Typical LoDFrom ppb to sub-ppm level, depending on gas
Dynamic rangeTypically 5 orders of magnitude, approximately 100,000 × detection limit
Response timeConfigurable from 15 seconds to several minutes
RecalibrationRecommended interval of 12 months
CommunicationEthernet / AK protocol, optional 4–20 mA analogue outputs
Portable versionOptional 19-inch 3U enclosure; approximately 18 kg with analyser; external power required
GASERA ONE dimensions / weight48 × 14 × 45 cm, approximately 13 kg depending on model

Note: filter configuration, ranges and interferences must be confirmed for the specific application.

Would you like to check whether PULSE fits your application?

Send the gas list, required ranges, sample matrix and operating conditions. MES-EKO will help select the GASERA ONE PULSE analyser configuration.

Contact MES-EKO
MES-EKO Sp. z o.o.
M. Skłodowskiej-Curie 55/61, 50-369 Wrocław
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl