Ethanol from the fuel system
Measurement of emissions associated with fuels containing biocomponents, such as E10.
A dedicated multi-gas analyser for direct monitoring of fuel-vapour emissions in SHED chambers and evaporative-emission testing. It simultaneously and selectively measures ethanol, methanol and the refrigerants R-134a and HFO-1234yf.
ONE SHEDSHED testing quantifies evaporative emissions from a vehicle fuel system and installation during type approval and vehicle development.
The analyser draws the sample directly from the SHED chamber and records concentration changes throughout the temperature cycle. No laboratory sample collection or sample preparation is required.
Measurement of emissions associated with fuels containing biocomponents, such as E10.
Distinguishing methanol from ethanol reduces the risk of false-positive results.
Simultaneous monitoring of R-134a and HFO-1234yf during air-conditioning leak tests.
Assessment of materials, lines, tanks and vehicle components for evaporative emissions.
A high-resolution laser source selectively distinguishes compounds that form a difficult mixture for conventional filter-based analysers.
An external-cavity quantum cascade laser scans multiple absorption lines in the Mid-IR, while the MEMS cantilever sensor detects very small photoacoustic signals.
Conventional PAS analysers with broadband sources and filters have limited ability to distinguish ethanol and methanol and often require nitrogen purging. GASERA ONE SHED uses a high-resolution laser and does not require N₂ purging to reduce CO₂ and moisture effects.
The manufacturer presents comparative tests and a three-day CARB cycle demonstrating simultaneous measurement of all four components.

For ethanol measurement, GASERA ONE SHED achieved lower peak-to-peak variation and lower standard deviation than a filter-based analyser.

Results show stable, simultaneous tracking of MeOH, EtOH, HFO-1234yf and R-134a as chamber temperature changes from 18 to 40 °C.
The exact interfaces, ranges and integration times must be confirmed when selecting the test system.
| Parameter | Information |
|---|---|
| Measured components | Ethanol, methanol, R-134a and HFO-1234yf, measured simultaneously and selectively |
| Detection limits | EtOH 23 ppb; MeOH 24 ppb; R-134a 7 ppb; HFO-1234yf 7 ppb |
| Measurement principle | Infrared photoacoustic spectroscopy with an optical MEMS cantilever sensor |
| Light source | External-cavity quantum cascade laser (EC-QCL) |
| Background measurement | Reduced H₂O and CO₂ influence; full pressure compensation |
| Zero gas / purging | No continuous nitrogen purge required in a typical SHED application |
| Housing | 19-inch 3U, benchtop or 19-inch rack mounting |
| Dimensions / weight | 48.4 × 13.9 × 44 cm; approximately 13 kg |
| Display / memory | 7-inch WSVGA; storage for at least one year of continuous monitoring |
| Internal volume | Approximately 30 ml |
| Operating conditions | 0–40 °C, non-condensing humidity, IP20 |
| Communications | Ethernet, USB and AK protocol; integration with SHED test automation |
This description is based on manufacturer materials. Documentation is available from MES-EKO on request.
Send us the required components, ranges, chamber volume, temperature profile and automation communication method. MES-EKO will help select a complete configuration.
Contact MES-EKO