A dedicated multi-gas analyser for direct monitoring of fuel-vapour emissions in SHED chambers and evaporative-emission testing. It simultaneously and selectively measures ethanol, methanol and the refrigerants R-134a and HFO-1234yf.

GASERAONE SHED
GASERA ONE SHED — product view 2ONE SHED
4
Four gases measured selectively and simultaneouslyEtOH, MeOH, R‑134a, HFO‑1234yf
23
EthanolLoD 23 ppb
EC
EC‑QCL laserEPA/CARB-recognised photoacoustic technique
Ø
No nitrogen carrier gasTypical ppb-level sensitivity
↔
Interference compensationAK protocol for test-cell integration
19
SHED evaporative-emission tests19-inch 3U enclosure
Application

Fuel-vapour emission testing in SHED chambers

SHED testing quantifies evaporative emissions from a vehicle fuel system and installation during type approval and vehicle development.

🚗

Direct online measurement in the chamber

The analyser draws the sample directly from the SHED chamber and records concentration changes throughout the temperature cycle. No laboratory sample collection or sample preparation is required.

⛽

Ethanol from the fuel system

Measurement of emissions associated with fuels containing biocomponents, such as E10.

🧴

Methanol from service fluids

Distinguishing methanol from ethanol reduces the risk of false-positive results.

❄️

Refrigerants

Simultaneous monitoring of R-134a and HFO-1234yf during air-conditioning leak tests.

🧪

Development testing

Assessment of materials, lines, tanks and vehicle components for evaporative emissions.

Measured components

One analysis – four relevant gases

A high-resolution laser source selectively distinguishes compounds that form a difficult mixture for conventional filter-based analysers.

EtOHetanol · LoD 23 ppb
MeOHmetanol · LoD 24 ppb
R‑134aRefrigerant emissions
HFO‑1234yfCARB/EPA cycles
Measurement technology

CEPAS with a broadly tunable EC-QCL

An external-cavity quantum cascade laser scans multiple absorption lines in the Mid-IR, while the MEMS cantilever sensor detects very small photoacoustic signals.

1
Ethanol, methanol, R-134a and HFO-1234yfEvaporative emissions analyser
2
The EC-QCL scans a broad spectral rangeMeasured gases
3
EtOH, MeOH, R-134a and HFO-1234yf simultaneouslyBrochure LoD
4
23 ppb; 24 ppb; 7 ppb; 7 ppb respectivelyResponse time
5
EPA/CARB-recognised photoacoustic techniqueDependent on channel integration and gas exchange

Why use an EC-QCL rather than optical filters?

Conventional PAS analysers with broadband sources and filters have limited ability to distinguish ethanol and methanol and often require nitrogen purging. GASERA ONE SHED uses a high-resolution laser and does not require N₂ purging to reduce CO₂ and moisture effects.

Typical ppb-level sensitivity A direct analyser for simultaneous evaporative-emission measurements inside a SHED chamber, avoiding impinger benches and remote laboratory analysis.
ppb Broadly tunable EC-QCL and CEPAS multi-component analysis separating EtOH, MeOH, R-134a and HFO-1234yf.
0 × N₂ GASERA ONE SHED is configured for Ethanol, methanol, R-134a and HFO-1234yf.
24/7automatic operation
Application results

Validated in a real SHED chamber

The manufacturer presents comparative tests and a three-day CARB cycle demonstrating simultaneous measurement of all four components.

GASERA ONE SHED — product view 3

Lower noise than conventional PAS

For ethanol measurement, GASERA ONE SHED achieved lower peak-to-peak variation and lower standard deviation than a filter-based analyser.

GASERA ONE SHED — product view 4

Three-day CARB test

Results show stable, simultaneous tracking of MeOH, EtOH, HFO-1234yf and R-134a as chamber temperature changes from 18 to 40 °C.

Technical data

Key GASERA ONE SHED specifications

The exact interfaces, ranges and integration times must be confirmed when selecting the test system.

ParameterInformation
Measured componentsEthanol, methanol, R-134a and HFO-1234yf, measured simultaneously and selectively
Detection limitsEtOH 23 ppb; MeOH 24 ppb; R-134a 7 ppb; HFO-1234yf 7 ppb
Measurement principleInfrared photoacoustic spectroscopy with an optical MEMS cantilever sensor
Light sourceExternal-cavity quantum cascade laser (EC-QCL)
Background measurementReduced H₂O and CO₂ influence; full pressure compensation
Zero gas / purgingNo continuous nitrogen purge required in a typical SHED application
Housing19-inch 3U, benchtop or 19-inch rack mounting
Dimensions / weight48.4 × 13.9 × 44 cm; approximately 13 kg
Display / memory7-inch WSVGA; storage for at least one year of continuous monitoring
Internal volumeApproximately 30 ml
Operating conditions0–40 °C, non-condensing humidity, IP20
CommunicationsEthernet, USB and AK protocol; integration with SHED test automation

Designing or upgrading a SHED test facility?

Send us the required components, ranges, chamber volume, temperature profile and automation communication method. MES-EKO will help select a complete configuration.

Contact MES-EKO
MES-EKO Sp. z o.o.
SHED evaporative-emission tests. Final performance depends on the selected gases, sample matrix and operating conditions.
tel. (+48) 71 348 64 02 · meseko@meseko.pl · www.meseko.pl