Continuous and portable oxygen measurement in processes, biogas, flue gas and mixtures, from trace levels to volume percent.

Applications

Oxygen is a fundamental parameter for combustion control, leak detection, technical-gas quality and process safety. In biogas it can indicate air ingress; in flue gas it supports combustion assessment and emission normalisation. Selection depends on the range, sample temperature, combustible gases, required selectivity and whether the instrument is stationary, portable or part of a multi-gas system.

Processes and technical gases

Control purity, inerting, tightness and mixture composition.

Biogas and fermentation

Monitor air ingress and biological process conditions.

Combustion and emissions

Measure O₂ for process control and emission reference calculations.

How to select method and range

Paramagnetic measurement provides selective, stable O₂ analysis without a consumable chemical sensor. Zirconia sensors suit many continuous process applications and can provide fast response. Electrochemical cells are practical in selected portable and multi-gas configurations, but have a finite lifetime and require interference checks. Combustible and reducing gases also influence method selection.

Trace, low-percent or 0–25% O₂ range
Paramagnetic, zirconia or electrochemical method
Sample composition and combustible gases
Stationary system, portable check or OEM integration

Sample-system design

Reliable results depend on leak-tight tubing, stable flow and prevention of ambient-air ingress. A small leak can dominate a trace-O₂ measurement. MES-EKO selects pressure reduction, filtration, drying or bypass components and integrates analyser signals with the control system.

Before configuration selection: trace, low-percent or 0–25% o₂ range, paramagnetic, zirconia or electrochemical method, sample composition and combustible gases, stationary system, portable check or oem integration.

Frequently asked questions

Answers to questions that arise before selecting a configuration.

When should a paramagnetic O₂ analyser be selected?

When selective, stable continuous measurement is required without periodic replacement of an electrochemical cell, provided the sample suits the method.

Why is trace oxygen measurement demanding?

A small sample-path leak or air diffusion can materially increase the reading, so the complete system must be exceptionally tight.

Related solutions

Explore pages covering related processes and measurement systems.

Technical sources

Method and instrument information was checked against manufacturer materials.

Discuss your measurement with MES-EKO

Send the measured components, range, sample conditions and operating mode. We will select the method, analyser and required system components.