Fresh carbon
The activated-carbon filter reduces VOCs to below 5 ppm and the analyser confirms correct performance.
An automatic micro gas chromatograph for continuous VOC monitoring in biogas-upgrading plants. It verifies activated-carbon filter performance, detects breakthrough and protects the quality and odorability of biomethane intended for grid injection.
PicoGC VOCRaw biogas VOC concentrations can reach 5,000 ppm. If they are not removed effectively, VOCs may clog the upgrading system and interfere with biomethane odorisation.
The activated-carbon filter reduces VOCs to below 5 ppm and the analyser confirms correct performance.
PicoGC alternates between two downstream sample points and tracks changes in marker compounds.
A rapid VOC increase triggers an alarm and identifies the filter that needs replacement.

Typical trend: VOC concentration increases rapidly after carbon saturation. Continuous monitoring uses the full carbon charge without compromising protection of the upgrading plant.
Each listed compound has a 0-100 ppm range and a stated 1 ppm detection limit. Other VOCs may be available on request.
The analyser operates close to two sample points in the ATEX area, while the Remote Control Box stores, processes and transfers data to the control room or Pollution Guardian cloud.

The VOC version shares the robust mechanical architecture of PicoGC THT-TBM, but uses its own chromatographic method, two sample inlets and a configuration dedicated to upgrading-plant protection.
Carrier gas is grade 5.5 helium or hydrogen. At four analyses per hour, a 14 L / 200 bar cylinder can last up to 10 or 9 years respectively.

Two 1/8-inch connections enable alternating supervision of two streams downstream of the carbon filters.
Recommended 20-100 mbarg, maximum 1.5 barg; consumption 13 mL/min at 20 mbar; H2O below 2,000 ppm and particles below 2 µm.
Automatic measurement, alarming and data transfer reduce manual sampling and premature carbon replacement.
Key analyser, sample, carrier-gas, power and communication parameters.
| Complete technical specifications | ||
|---|---|---|
| Application | automatic gas chromatograph for VOC monitoring | |
| Functions | chromatogram acquisition, alarm management and continuous monitoring; analogue and digital I/O status, data protection, PLC communication and supervision, remote server and wireless connectivity | |
| Inputs/Outputs - RCB | 1 × RS485 Modbus ASCII/RTU (optional); 1 × Ethernet TCP/IP Modbus / Web APIs; Wi-Fi; 4G | |
| Inputs/Outputs - GC | 1 × power supply and data RJ45 (Ethernet) | |
| Supported protocols | Modbus TCP/IP; Web APIs; Modbus RTU (optional) | |
| ATEX GC enclosure | IP66; 450 × 350 × 251 mm; below 27 kg | |
| Certifications | CE ATEX II 2G Ex db IIB+H2 T6 Gb; IECEx Ex db IIB+H2 T6 Gb | |
| RCB enclosure | IP66; 325 × 428.2 × 178 mm; 4 kg | |
| Carrier gas connection | 1 × carrier-gas inlet, 1/8-inch OD Swagelok type | |
| Process gas connections | 2 × sample-gas inlet, 1/8-inch OD Swagelok type | |
| Carrier gas | helium (He) or hydrogen (H2); 14 L / 200 barg He cylinder: up to 10 years at 4 analyses/hour; 14 L / 200 barg H2 cylinder: up to 9 years at 4 analyses/hour; minimum purity Grade 5.5 (≥99.9995%); pressure 3.5 ±0.5 barg | |
| Sample gas conditions | recommended pressure 20-100 mbarg; maximum 1.5 barg; consumption 13 ml/min at 20 mbar (excluding fast-loop bypass, if required); free of particulates and liquids; H2O <2000 ppm; particulates Ø <2 µm | |
| Analysed compound | Range | Limit of detection (S/N = 3) |
|---|---|---|
| Acetone | 0-100 ppm | LOD 1 ppm |
| 2-Butanone - MEK | 0-100 ppm | LOD 1 ppm |
| Benzene | 0-100 ppm | LOD 1 ppm |
| Toluene | 0-100 ppm | LOD 1 ppm |
| Ethylbenzene | 0-100 ppm | LOD 1 ppm |
| Xylenes (o-, p-, m-) | 0-100 ppm | LOD 1 ppm |
| Pinene (alpha and beta) | 0-100 ppm | LOD 1 ppm |
| o,p-Cymene | 0-100 ppm | LOD 1 ppm |
| Limonene | 0-100 ppm | LOD 1 ppm |
| 3-Carene | 0-100 ppm | LOD 1 ppm |
| Data logging | concentration storage with configurable lower and upper alarms | |
|---|---|---|
| Chromatogram storage | more than 3 years of continuous measurements with configurable lower and upper alarms | |
| Language | English | |
| Operating temperature | -35°C to +60°C; outdoor installation | |
| Power supply | 24 V supplied by external RCB, included; automatic restart after power interruption | |
| Nominal power consumption | 35 W at 0°C; maximum instantaneous power draw 90 W | |
| Analysis time | below 300 seconds | |
Provide the biogas composition, upgrading technology, carbon-filter arrangement, sampling points and required automation interface.