Target vehicle
The measurement vehicle follows a selected target vehicle in real traffic.
Plume Chasing and transport-emission monitoring without stopping vehicles
The range covers rapid measurements of individual vehicles as well as complementary mobile, spatial and fixed methods for monitoring the impact of transport emissions on air quality.

The mobile method combines diluted-plume sampling, fast gas analysis and automatic calculation of an emission factor for the target vehicle.
Plume Chasing is a method for measuring vehicle emissions under real-driving conditions. A measurement vehicle follows a selected vehicle and samples its diluted exhaust plume. Simultaneous CO₂ measurement helps identify an emission event and interpret changing plume dilution, while NO, NO₂ and NOx signals describe nitrogen-oxide emissions.
This approach to transport-emission monitoring supports rapid fleet screening and the identification of high-emitting vehicles without diverting them to a stationary test facility. It is a screening method, not a substitute for type-approval or certification testing. The solution uses AIRYX instrumentation from the ICAD family.
The measurement vehicle follows a selected target vehicle in real traffic.
The exhaust mixes with ambient air and forms a dynamic measurement plume.
A probe mounted on the measurement vehicle samples the diluted exhaust gas.
ICAD measures nitrogen oxides, while CO₂ identifies the plume and accounts for dilution.
The software calculates the emission factor and evaluates the recorded event.
The method is designed for rapid screening of vehicle emissions under normal driving conditions.

Plume Chasing is the dedicated application of ICAD-NOx-210DE. The other technologies complement it with mobile, spatial or fixed monitoring.

Individual vehicles and rapid calculation of a vehicle emission factor.
View solution →
Mobile NO, NO₂ and NOx monitoring without the dedicated Plume Chasing configuration.
View analyser →
Spatial and mobile monitoring of atmospheric NO₂ distributions.

Fixed monitoring of roads, ports and transport corridors along a defined path.
View Open Path →The appropriate method depends on whether the result must be linked to a specific vehicle, represent a larger group of sources or describe the effect of transport on ambient air.
The measurement vehicle follows a selected target and records its diluted plume. The method supports vehicle-specific event identification and screening of a larger number of vehicles during a campaign.
A station beside the road measures ambient concentrations shaped by the entire traffic stream and atmospheric conditions. The result describes air quality at the site rather than assigning emissions directly to one vehicle.
An analyser moving along a selected route shows how concentrations vary in space. It is useful for mapping an area and locating zones with a stronger transport influence.
A measurement along a defined optical path supports long-term observation of a road, port or transport corridor. It covers the complete measurement path rather than the emission of an individual vehicle.
SkySpec systems observe the spatial distribution of atmospheric NO₂. They provide a wider-area view and complement point or mobile measurements, but they are not Plume Chasing systems.
Testing an individual prepared vehicle enables a detailed test scenario under controlled conditions or with on-board instrumentation. It addresses a different objective from rapid field screening of many vehicles.
The choice depends on whether the target is an individual vehicle, mobile analysis, a spatial image or fixed observation of a road section.
| Measurement task | Recommended method |
|---|---|
| Identify vehicles with elevated emissions | ICAD-NOx-210DE |
| Mobile NOx measurements | ICAD-NOx-210D |
| Image the spatial distribution of NO₂ | SkySpec 2D |
| Mobile atmospheric remote sensing | SkySpec Compact |
| Fixed monitoring of a road section | Open Path |
| Ports and transport corridors | Open Path / SkySpec |
ICAD-NOx-210DE is the primary choice for Plume Chasing, fleet screening or identifying high-emitting vehicles through simultaneous NOx and CO₂ measurement.
ICAD-NOx-210D is better suited to mobile NO, NO₂ and NOx campaigns that do not require a dedicated configuration for deriving an emission factor for a specific vehicle.
SkySpec 2D and SkySpec Compact are appropriate when the objective is a spatial image of NO₂ or mobile atmospheric remote sensing rather than plume sampling behind a selected vehicle.
Open Path is intended for fixed observation of a defined road section, facility boundary, port or transport corridor.
We select the technology according to campaign scale, measurement geometry, required time resolution and reporting approach.
Measurements made during normal operation capture emission events under changing engine load, speed and road conditions.
A series of short measurement events can cover a larger vehicle group efficiently and identify cases that merit further investigation.
Plume Chasing helps identify vehicles that stand out within the measured group without interrupting their normal journey.
Ambient measurements beside a road describe the combined influence of traffic at a location and can complement campaigns focused on individual vehicles.
Mobile, spatial and fixed measurements help assess how traffic-related pollution varies along streets and around major routes. See also our air-quality monitoring solutions.
Open Path and remote-sensing methods can cover access roads, operational areas and transport corridors influenced by multiple mobile sources.
Combining several methods supports analysis of temporal and spatial relationships and comparison between different measurement geometries.
A consistent campaign protocol can be used to study emission signatures from vehicles with different powertrains and exhaust aftertreatment systems.
Concise answers about Plume Chasing, roadside monitoring and selecting technology for a measurement campaign.
It is a mobile vehicle-emission screening method in which a measurement vehicle follows a selected target and samples its diluted exhaust plume. The results help identify emission events and high-emitting vehicles; the method is not a substitute for type-approval testing.
A probe on the measurement vehicle samples the plume, the analyser records NO, NO₂, NOx and CO₂, and the software identifies the event and calculates an emission factor for the observed pass.
No. Measurement takes place while following the target vehicle, so it does not need to be diverted to a stationary test facility. Campaign planning must still account for road safety and suitable measurement conditions.
The dedicated ICAD-NOx-210DE configuration measures NO, NO₂, NOx and CO₂. Other measurement objectives may require a different analyser or a complementary technology.
An increase in CO₂ helps identify the presence of an exhaust plume. The relationship between NOx and CO₂ signals supports interpretation of the result as plume dilution changes in ambient air.
Plume Chasing follows an event associated with a selected vehicle. Roadside monitoring measures combined ambient concentrations influenced by many vehicles, meteorology and other local sources.
Yes, a campaign can include light- and heavy-duty vehicles. The configuration, classification approach and driving conditions must be matched to the study objective and traffic environment.
First define whether the target is an individual vehicle, fleet screening, a spatial NO₂ image or continuous monitoring of a section. Measurement geometry, time resolution, campaign scale and reporting requirements can then be selected accordingly.
We will match the method to the number of vehicles, required time resolution, measurement location and presentation of results.