TECNOCONTROL · MES-EKO

EasyGas PGD100 — portable single-gas detector

Portable detector for personal protection. Each unit is configured for one gas. It warns the wearer using visual, audible and vibration alarms.

EasyGas PGD100 H₂S version — front viewEASYGAS PGD100
One gasSensor selected for the hazard
Three alarm modesVisual, audible and vibration
1.6″ LCDLive concentration reading
105 gWeight with clip
IP68Enclosure protection

Industrial applications

Wastewater treatment and biogas plants

Personal monitoring for H₂S or oxygen, depending on the hazards at the worksite.

Power generation and industry

Warning of exposure to a selected gas, such as CO near combustion equipment.

Chemical plants

Selection for a specific substance, such as NH₃ or Cl₂ where present.

Service and maintenance

Worn by staff working near a known gas hazard.

Workplace monitoring

Live readings for the selected gas in the air around the wearer.

Measurement, alarms and operation

EasyGas PGD100 H₂S — angled view of the display and alarm LEDs

Measurement at the wearer

Gas reaches the electrochemical sensor and the detector displays the concentration in ppm or vol.%, depending on the version. The version is selected for the target gas before purchase.

Alarm signalling

When the concentration reaches a configured threshold, the detector alerts the wearer using LEDs, vibration and sound (approximately 100 dB at 10 cm). Low and high thresholds are available, with TWA and STEL alarms on applicable versions.

EasyGas PGD100 H₂S — rear of the housing with the metal clip

Attachment and supplied items

Use the rear clip to attach the detector to workwear. Wear it in the breathing zone and keep the gas inlet clear. The standard package includes the detector with clip, a gas calibration cap and a quick-start guide.

Operation and self-test

A button operates the menu. The display indicates battery status, alarms and faults; the self-test checks the sensor, circuitry and battery. Authorised staff change alarm thresholds according to site procedures.

The photos show the H₂S version. The marking on the housing depends on the gas version ordered.

Gas versions and measuring ranges

These codes identify separate versions. All listed versions use an electrochemical sensor selected for the target gas.

Gas versions and measuring ranges
Gas and model codeRangeResolution
O₂ · oxygenPGD100-O20–30 vol.%0.1 vol.%
O₂ · lead-free sensorPGD100-O2LF0–30 vol.%0.1 vol.%
CO · carbon monoxidePGD100-CO0–1000 ppm1 ppm
CO · extended rangePGD100-COE0–2000 ppm1 ppm
CO · H₂ compensationPGD100-COH0–500 ppm1 ppm
H₂S · hydrogen sulfidePGD100-H2S0–100 ppm0.1 ppm
H₂ · hydrogenPGD100-H20–1000 ppm1 ppm
SO₂ · sulfur dioxidePGD100-SO20–20 ppm0.1 ppm
Cl₂ · chlorinePGD100-Cl20–50 ppm0.1 ppm
HCl · hydrogen chloridePGD100-HCL0–15 ppm0.1 ppm
HCN · hydrogen cyanidePGD100-HCN0–100 ppm0.1 ppm
PH₃ · phosphinePGD100-PH30–20 ppm0.1 ppm
ETO · ethylene oxidePGD100-ETO0.1 ppm
O₃ · ozonePGD100-O30–5 ppm0.01 ppm
NO · nitric oxidePGD100-NO0–250 ppm1 ppm
NO₂ · nitrogen dioxidePGD100-NO20–30 ppm0.1 ppm
NH₃ · ammoniaPGD100-NH30–100 ppm1 ppm
NH₃ · extended rangePGD100-NH3E0–1000 ppm1 ppm

Technical specifications

Display1.6″ FSTN LCD
Dimensions66 × 69 × 24 mm without clip; 66 × 69 × 41 mm with clip
Weight105 g with clip
Relative humidity0–95% RH, non-condensing
Operating temperatureMost versions: −30 to +50 °C. Cl₂, O₃ and ETO: −20 to +50 °C. NH₃ and NH₃E: −40 to +50 °C. O₂LF: −40 to +60 °C.
Enclosure protectionIP68

Battery, sensor and periodic checks

Battery and operating time

3.6 V, 1.65 Ah lithium cell (2/3 AA). Over 2 years without battery replacement in a profile of 8 hours of use per day, with up to 5 minutes of alarm activity and BLE switched off. Actual runtime depends on use.

Arrange replacement with Tecnocontrol. Only authorised personnel should replace the battery, in a safe area and in accordance with the manufacturer’s procedure.

Sensor and warranty

The instrument has a two-year warranty from purchase. Tecnocontrol lists a two-year sensor warranty for O₂, CO, H₂S, NO₂ and PH₃, and one year for H₂, NO, SO₂, Cl₂, NH₃, O₃, HCl, HCN and ETO.

The warranty period does not establish sensor life. Service life depends on the version and exposure conditions.

Bump test and calibration

Before use, the manufacturer recommends a bump test with gas above the alarm threshold. It checks detector response and alarm signalling.

Calibration adjusts the readings. The manufacturer recommends gas calibration at least every 180 days, following the procedure for the specific sensor. Also follow site procedures and act on test results.

Certification and safety

Ex markings

For versions listed in the certificates: ATEX KSCP 24ATEX0031X (II 1G Ex ia IIC T4 Ga) and IECEx KSCP 24.0053X (Ex ia IIC T4 Ga). Before use, verify the variant code, unit marking, special conditions X and sensor operating temperature. Do not open the enclosure in an explosive atmosphere; follow the documented electrostatic precautions.

Confined spaces

The detector can help protect against one selected hazard. On its own, it does not provide full atmospheric monitoring before entry or during work. Entry procedures and monitoring must cover all hazards identified for the site.

Technical selection

EasyGas PGD100 — selection with MES-EKO

We can help select the EasyGas PGD100 for the hazards at your worksite.

What we review

  • Gas and rangeSelect a single-gas version for the substance and expected concentrations.
  • Operating conditionsConsider the workplace conditions and any required Ex marking.
  • Alarm requirementsDiscuss alarm configuration and the detector check requirements.

Selection and integration with MES-EKO

Tell us the target gas, installation location and alarm requirements. We can help select the device and plan the integration.